The clearance of medical devices by the US Food and Drug Administration (FDA) has remained largely unchanged since 1976, when the Medical Device Amendments Act established a system classifying devices into 3 categories based on safety risk to the consumer. The system allows for the clearance of many orthopedics devices through the 510(k) premarket pathway, which is based on "predicate ancestors," previously cleared devices that are "substantially equivalent." : We sought to trace the predicate ancestors of modern total knee arthroplasty (TKA) devices, specifically those recently cleared for marketing by the 510(k) pathway that claim substantial equivalence to prior devices, despite potential differences in material science and design. In addition, we aimed to document which TKA devices cleared by the 510(k) pathway have substantial equivalence to devices that have since been recalled by the FDA. : To create a comprehensive list of TKA devices, we used FDA Classification Process Codes corresponding to knee arthroplasty to search the FDA's databases from May 28, 1976, the start of the 510(k) process, to May 1, 2021. Of 1309 resulting devices, 89 were excluded as not related to arthroplasty. For each of the remaining devices, we analyzed the descendant devices that claimed substantial equivalence, either directly or indirectly. We used data of recalled designs to determine both the absolute number of recalled devices and the number of currently cleared devices that presented substantial equivalence claims upon predicates that have since been recalled. : Of 1220 knee devices cleared or approved, 6 (0.5%) were approved through the premarket approval application (PMA) process, and 1214 (99.5%) were cleared through the 510(k) pathway. Of the 1214 cleared devices, 217 (17.9%) have been recalled and 204 (16.8%) have ties to at least 1 recalled predicate device linked through generational claims of substantial equivalence. We found 90 devices (7.4%) linked directly to a recalled predicate device. : Most knee arthroplasty devices are cleared for marketing through reliance on a complex web of equivalency to previously cleared predicates. We found that many TKA devices thus connected were cleared decades apart, with multiple iterations of design and material modifications. Many currently marketed TKA devices have claimed equivalency to predicates that have been recalled. Our findings suggest the need for novel regulatory strategies that might further patient safety while balancing the unwanted effects of regulatory burden.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9527547PMC
http://dx.doi.org/10.1177/15563316221099014DOI Listing

Publication Analysis

Top Keywords

devices
20
tka devices
20
substantial equivalence
20
knee arthroplasty
16
devices cleared
16
cleared devices
12
510k pathway
12
cleared
10
cleared marketing
8
cleared 510k
8

Similar Publications

Purpose: RVVC is defined as four or more episodes of candidiasis in a 12-month period. Conventional treatment is complex and often involves long-term medication use or multiple treatments. ABL therapy is a promising treatment option as it is acceptable to women and has only rare side effects.

View Article and Find Full Text PDF

Morphea is a chronic inflammatory fibrosing disorder. Since fibrosis is the hallmark of both scars and morphea, our attention was raised for the possible use of Fractional Ablative CO lasers and microneedling as treatment modalities for morphea. To compare the efficacy and safety of Fractional Ablative CO lasers and microneedling in the treatment of morphea.

View Article and Find Full Text PDF

Novel Therapies for Right Ventricular Failure.

Curr Cardiol Rep

January 2025

Pediatric Advanced Heart Failure and Heart Transplant Program, University of Mississippi Medical Center, 2500 N State Street, Jackson, MS, USA.

Purpose Of Review: Traditionally viewed as a passive player in circulation, the right ventricle (RV) has become a pivotal force in hemodynamics. RV failure (RVF) is a recognized complication of primary cardiac and pulmonary vascular disorders and is associated with a poor prognosis. Unlike treatments for left ventricular failure (LVF), strategies such as adrenoceptor signaling inhibition and renin-angiotensin system modulation have shown limited success in RVF.

View Article and Find Full Text PDF

Introduction: Blunt traumatic aortic injury (TAI) is a critical condition and a leading cause of mortality in trauma patients, often resulting from high-speed accidents. Thoracic endovascular aortic repair (TEVAR) has developed into the preferred therapeutic approach due to its minimally invasive nature and promising outcomes. This study evaluates the safety and efficacy of TEVAR for managing TAI over a 10-year period at a Level-1 trauma center.

View Article and Find Full Text PDF

Thermophysical properties of graphene reinforced with polymethyl methacrylate nanoparticles for technological applications: a molecular model.

J Mol Model

January 2025

Escuela Superior de Física y Matemáticas, IPN S/N, Edificio 9 de la Unidad Profesional "Adolfo López Mateos", Col. Lindavista, Alc. Gustavo A. Madero, 07738, Mexico City, Mexico.

Context: "Nanostructure of graphene-reinforced with polymethyl methacrylate" (PMMA-G), and vice versa, is investigated using its molecular structure, in the present work. The PMMA-G nanostructure was constructed by bonding PMMA with graphene nanosheet in a sense to get three different configurations. Each configuration consisted of polymeric structures with three degrees of polymerization (such as monomers, dimers, and trimers polymers, respectively).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!