Optical parametric chirped-pulse amplification (OPCPA) is an effective way to generate ultrashort pulses that has been used extensively for a variety of applications requiring high peak intensities. Precise control and measurement of a system's spectral and spatial phases are required for Fourier-transform-limited pulse compression and diffraction-limited focusing. Phase accumulated during optical parametric amplification (OPA) can degrade the compressibility and focusability of the pulse, reducing peak intensity. We used analytic and numerical analysis of OPA to study the influence of crystal parameters, the wavefront of the pump and signal, and their relative optical alignment on the accumulated phase. We show that the accumulated signal phase is largely independent of amplifier saturation and, with significant local wavefront gradients in the signal or pump beam, the quality of the compressed pulses can be degraded. We use first-order expressions for the pump- and signal-angle sensitivity to evaluate an OPCPA system consisting of a highly deuterated potassium dihydrogen phosphate amplifier designed to support bandwidth for 15 fs pulses centered at 920 nm.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.455006DOI Listing

Publication Analysis

Top Keywords

optical parametric
12
parametric amplification
8
pulse compression
8
phase accumulated
8
impact optical
4
phase
4
amplification phase
4
phase laser
4
laser pulse
4
compression optical
4

Similar Publications