For large ground-based telescopes, static and dynamic disturbances would greatly degrade the optical performance. This is especially true for wide field survey telescopes with prime focus optics. The estimation of disturbance effects on large telescopes is becoming increasingly important during the design phase. Therefore, a wide field survey telescope with 2.5 m aperture and 3.5 deg field of view is studied in this research. This telescope is under construction now, and its first light is expected at the beginning of 2023. The estimation method for the optical performance under static and dynamic disturbances in the temporal domain and the active compensation method to improve the optical alignment, are investigated, which is a supplement for the simulation in the frequency domain. First, based on the mechanical model, the optical misalignment is established, where the deviation of the primary mirror is obtained from the length gauges and the deviation of the corrector is computed using the fitting method. Second, a method for compensating the static and dynamic disturbances is proposed, improving the optical performance. This method uses the disturbed primary mirror as the reference, and the corrector is actively controlled to align with it. Finally, a series of experimental tests and numerical simulations is conducted. The results show that the mechanical modeling error is within 10% and the maximum optical misalignment is reduced from 12/0.27 to 0.2/0.006 for static disturbance and from 1.3/0.03 to 0.4/0.01 for dynamic disturbance. Through active compensation, the telescope optical property is greatly improved. The modeling method and the simulation process mentioned in this research can also be used in the other relevant fields.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.456684DOI Listing

Publication Analysis

Top Keywords

static dynamic
16
optical misalignment
12
wide field
12
field survey
12
dynamic disturbances
12
optical performance
12
dynamic disturbance
8
optical
8
large ground-based
8
survey telescope
8

Similar Publications

Radioactive molecular iodine (I) is a critical volatile pollutant generated in nuclear energy applications, necessitating sensors that rapidly and selectively detect low concentrations of I vapor to protect human health and the environment. In this study, we design and prepare a three-component sensing material comprising reduced graphene oxide (rGO) as the substrate, silver iodide (AgI) particles as active sites, and polystyrene sulfonate as an additive. The AgI particles enable reversible adsorption and conversion of I molecules into polyiodides, inducing substantial charge density variation in rGO.

View Article and Find Full Text PDF

Solid-state detector single photon emission computed tomography (SPECT) enables the acquisition of dynamic data for calculation of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Here, we report about our experiences on routine clinical use and robustness using Tc-99 m-sestamibi and Tc-99 m-tetrofosmin. 307 patients underwent dynamic list-mode myocardial perfusion imaging (MPI) and standard static MPI for clinical workup of coronary artery disease on a dedicated cardiac SPECT camera.

View Article and Find Full Text PDF

Utility of physiologically based pharmacokinetic modeling in predicting and characterizing clinical drug interactions.

Drug Metab Dispos

January 2025

Pharmacokinetics, Dynamics, Metabolism and Bioanalytics, Merck & Co, Inc, Boston, Massachusetts. Electronic address:

Physiologically based pharmacokinetic (PBPK) modeling is a mechanistic dynamic modeling approach that can be used to predict or retrospectively describe changes in drug exposure due to drug-drug interactions (DDIs). With advancements in commercially available PBPK software, PBPK DDI modeling has become a mainstream approach from early drug discovery through to late-stage drug development and is often used to support regulatory packages for new drug applications. This Minireview will briefly describe the approaches to predicting DDI using PBPK and static modeling approaches, the basic model structures and features inherent to PBPK DDI models, and key examples where PBPK DDI models have been used to describe complex DDI mechanisms.

View Article and Find Full Text PDF

Diagnostic ultrasonography of upper extremity dynamic compressive neuropathies in athletes: A narrative review.

Int Orthop

January 2025

Physical Medicine and Rehabilitation Division, Department of Orthopaedic Surgery, Stanford University, Redwood City, CA, USA.

Purpose: This narrative review identifies and summarizes current evidence for diagnostic ultrasonographic evaluation of upper extremity dynamic compressive neuropathies affecting athletes.

Methods: Relevant literature was identified using the PubMed database and then summarized.

Results: The compressive neuropathies affecting athletes we identified included: neurogenic thoracic outlet syndrome, pectoralis minor syndrome, quadrilateral space syndrome, suprascapular nerve entrapment, proximal median nerve entrapment or bicipital aponeurosis/lacertus fibrosus (lacertus syndrome), radial tunnel syndrome, and cubital tunnel syndrome.

View Article and Find Full Text PDF

Solitary foraging insects like desert ants rely heavily on vision for navigation. While ants can learn visual scenes, it is unclear what cues they use to decide if a scene is worth exploring at the first place. To investigate this, we recorded the motor behavior of Cataglyphis velox ants navigating in a virtual reality set-up (VR) and measured their lateral oscillations in response to various unfamiliar visual scenes under both closed-loop and open-loop conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!