Background: A clear patency benefit of a drug-eluting stent (DES) over bare metal stents (BMSs) for treating peripheral artery disease of the femoropopliteal segment has not been definitively demonstrated. The EMINENT study (Trial Comparing Eluvia Versus Bare Metal Stent in Treatment of Superficial Femoral and/or Proximal Popliteal Artery) was designed to evaluate the patency of the Eluvia DES (Boston Scientific, Marlborough, MA), a polymer-coated paclitaxel-eluting stent, compared with BMSs for the treatment of femoropopliteal artery lesions.

Methods: EMINENT is a prospective, randomized, controlled, multicenter European study with blinded participants and outcome assessment. Patients with symptomatic peripheral artery disease (Rutherford category 2, 3, or 4) of the native superficial femoral artery or proximal popliteal artery with stenosis ≥70%, vessel diameter of 4 to 6 mm, and total lesion length of 30 to 210 mm were randomly assigned 2:1 to treatment with DES or BMS. The primary effectiveness outcome was primary patency at 12 months, defined as independent core laboratory-assessed duplex ultrasound peak systolic velocity ratio ≤2.4 in the absence of clinically driven target lesion revascularization or surgical bypass of the target lesion. Primary sustained clinical improvement was a secondary outcome defined as a decrease in Rutherford classification of ≥1 categories compared with baseline without a repeat target lesion revascularization. Health-related quality of life and walking function were assessed.

Results: A total of 775 patients were randomly assigned to treatment with DES (n=508) or commercially available BMSs (n=267). Baseline clinical, demographic, and lesion characteristics were similar between the study groups. Mean lesion length was 75.6±50.3 and 72.2±47.0 mm in the DES and BMS groups, respectively. The 12-month incidence of primary patency for DES treatment (83.2% [337 of 405]) was significantly greater than for BMS (74.3% [165 of 222]; <0.01). Incidence of primary sustained clinical improvement was greater among patients treated with the DES than among those who received a BMS (83.0% versus 76.6%; =0.045). The health-related quality of life dimensions of mobility and pain/discomfort improved for the majority of patients in both groups (for 66.4% and 53.6% of DES-treated and for 64.2% and 58.1% of BMS-treated patients, respectively) but did not differ significantly. At 12 months, no statistical difference was observed in all-cause mortality between patients treated with the DES or BMS (2.7% [13 of 474] versus 1.1% [3 of 263]; relative risk, 2.4 [95% CI, 0.69-8.36]; =0.15).

Conclusions: By demonstrating superior 1-year primary patency, the results of the EMINENT randomized study support the benefit of using a polymer-based paclitaxel-eluting stent as a first-line stent-based intervention for patients with symptomatic peripheral artery disease attributable to femoropopliteal lesions.

Registration: URL: https://www.

Clinicaltrials: gov; Unique identifier: NCT02921230.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.122.059606DOI Listing

Publication Analysis

Top Keywords

bare metal
12
peripheral artery
12
artery disease
12
target lesion
12
drug-eluting stent
8
versus bare
8
metal stents
8
superficial femoral
8
proximal popliteal
8
popliteal artery
8

Similar Publications

Diabetes mellitus is one of the metabolic syndromes that is associated with cognitive deficit, dementia, and Alzheimer's disease (AD) like pathology due to impaired insulin-signalling in the brain, oxidative stress and mitochondrial dysfunction. Nanotechnology is one of the most promising techniques for targeting the brain. However, the toxicity of metal nanoparticles is one of the biggest challenges to be studied.

View Article and Find Full Text PDF

Buried interface engineering towards stable zinc anodes for high-performance aqueous zinc-ion batteries.

Sci Bull (Beijing)

December 2024

School of Metallurgy and Environment, Central South University, Changsha 410083, China; Engineering Research Center of the Ministry of Education for Advanced Battery Materials, Central South University, Changsha 410083, China; National Energy Metal Resources and New Materials Key Laboratory, Central South University, Changsha 410083, China. Electronic address:

The dendrite and corrosion issues still remain for zinc anodes. Interface modification of anodes has been widely used for stabilizing zinc anodes. However, it is still quite challenging for such modification to simultaneously suppress zinc dendrites and corrosion issues.

View Article and Find Full Text PDF

Microbial fuel cells (MFCs) are a candidate for green energy sources due to microbes' ability to generate charge in their metabolic processes. The main problem in MFCs is slow charge transfer between microorganisms and electrodes. Several methods to improve charge transfer have been used until now: modification of microorganisms by conductive polymers, use of lipophilic mediators, and conductive nanomaterials.

View Article and Find Full Text PDF

Aim This study aims to evaluate the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) check and revision procedures performed in a freestanding interventional radiology (IR) outpatient facility. Methodology A total of 40 patients (male 31:female 9, median age 60 years old) underwent a TIPS check and/or revision at a freestanding IR outpatient facility between 2009 and 2017. Procedures were performed using a mobile C-arm unit under intravenous (IV) moderate sedation, with the patient discharged home on the same day.

View Article and Find Full Text PDF

Novel metal oxides partially derived perovskite-structured hydroxides for room temperature trace NO gas sensors under UV irradiation.

Talanta

December 2024

Key Laboratory of Applied Chemistry and Nanotechnology at University of Jilin Province, Changchun University of Science and Technology, Changchun, 130022, China. Electronic address:

Perovskite-structured materials are used as gas-sensitive materials due to their wide bandgap and controllable morphology, but large initial resistance and low response limit their development. In this work, ZnSn(OH)/ZnO composites derived from ZnO were synthesized by hydrothermal method. The gas-sensitive results show that all sensors show significantly improved response to NO under UV irradiation compared with without UV irradiation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!