Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background Aims: Vector copy number (VCN), an average quantification of transgene copies unique to a chimeric antigen receptor (CAR) T-cell product, is a characteristic that must be reported prior to patient administration, as high VCN increases the risk of insertional mutagenesis. Historically, VCN assessment in CAR T-cell products has been performed via quantitative polymerase chain reaction (qPCR). qPCR is reliable along a broad range of concentrations, but quantification requires use of a standard curve and precision is limited. Digital PCR (dPCR) methods were developed for absolute quantification of target sequences by counting nucleic acid molecules encapsulated in discrete, volumetrically defined partitions. Advantages of dPCR compared with qPCR include simplicity, reproducibility, sensitivity and lack of dependency on a standard curve for definitive quantification. In the present study, the authors describe a dPCR assay developed for analysis of the novel bicistronic CD19 × CD22 CAR T-cell construct.
Methods: The authors compared the performance of the dPCR assay with qPCR on both the QX200 droplet dPCR (ddPCR) system (Bio-Rad Laboratories, Inc, Hercules, CA, USA) and the QIAcuity nanoplate-based dPCR (ndPCR) system (QIAGEN Sciences, Inc, Germantown, MD, USA). The primer-probe assay was validated with qPCR, ndPCR and ddPCR using patient samples from pre-clinical CAR T-cell manufacturing production runs as well as Jurkat cell subclones, which stably express this bicistronic CAR construct.
Results: ddPCR confirmed the specificity of this assay to detect only the bicistronic CAR product. Additionally, the authors' assay gave accurate, precise and reproducible CAR T-cell VCN measurements across qPCR, ndPCR and ddPCR modalities.
Conclusions: The authors demonstrate that dPCR strategies can be utilized for absolute quantification of CAR transgenes and VCN measurements, with improved test-retest reliability, and that specific assays can be developed for detection of unique constructs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10123956 | PMC |