A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Point-of-Care Noninvasive Technology for Pediatric Dehydration Assessment. | LitMetric

Objective: Dehydration is a commonly encountered problem worldwide. Current clinical assessment is limited by subjectivity and limited provider training with children. The objective of this study is to investigate a new noninvasive, point-of-care technology that measures capillary refill combined with patient factors to accurately diagnose dehydration.

Methods: This is a prospective observational study at a tertiary care children's hospital in Buenos Aires, Argentina. Patients were eligible if younger than 10 years who presented to the emergency department with vomiting and/or diarrhea whom the triage nurse deems to be potentially dehydrated. Patients had the digital capillary refill device done on presentation in addition to standard of care vital signs and weight. Patients had serial weights measured on hospital scales throughout their stay. The primary outcome was dehydration, which was calculated as a percent change in weight from admission to discharge.

Results: Seventy-six children were enrolled in the study with 56 included in the final analysis. A stepwise forward method selection chose malnutrition, temperature, and systolic blood pressure for the multivariable model. The area under the curve for the final model was fair (0.7431). To further look into the utility of such a device in the home setting where blood pressure is not available often, we reran the model without systolic blood pressure. The area under the curve for the final model was 0.7269.

Conclusions: The digital capillary refill point-of-care device combined with readily available patient-specific factors may improve the ability to detect pediatric dehydration and facilitate earlier treatment or transfer to higher levels of care.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PEC.0000000000002824DOI Listing

Publication Analysis

Top Keywords

capillary refill
12
blood pressure
12
pediatric dehydration
8
digital capillary
8
systolic blood
8
area curve
8
curve final
8
final model
8
point-of-care noninvasive
4
noninvasive technology
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!