Background: The appropriate use of the thyroglobulin (Tg) test involves the concurrent measurement of Tg auto-antibodies (Tg Ab) due to the potential for false low or false high Tg due to Tg Ab interference.

Methods: We retrospectively reviewed Tg and Tg Ab test results requested from local clinics and hospitals in Korea between July 1, 2020 and June 30, 2021.

Results: During the study period, 13,811 Tg tests were performed. Among them, 6,769 Tg tests were identified as being repeatedly measured from 2,988 Korean adults. Among the 6,769 performed Tg tests, 2,733 (40.4%) did not have concurrently performed Tg Ab tests. Among the 2,988 subjects, 1,089 (36.4%) had no concurrently measured Tg Ab test results. Among 4,036 Tg results with concurrently measured Tg Ab, 1,045 (25.9%) had positive Tg Ab results, which could interfere with Tg concentration measurements.

Conclusions: The Tg Ab test appears to be underutilized in Korea.

Download full-text PDF

Source
http://dx.doi.org/10.7754/Clin.Lab.2022.220119DOI Listing

Publication Analysis

Top Keywords

performed tests
8
concurrently measured
8
seroprevalence anti-thyroglobulin
4
anti-thyroglobulin antibodies
4
antibodies korea
4
korea background
4
background appropriate
4
appropriate thyroglobulin
4
test
4
thyroglobulin test
4

Similar Publications

Purpose: To develop and validate an MRI-based model for predicting postoperative early (≤2 years) recurrence-free survival (RFS) in patients receiving upfront surgical resection (SR) for beyond Milan hepatocellular carcinoma (HCC) and to assess the model's performance in separate patients receiving neoadjuvant therapy for similar-stage tumors.

Method: This single-center retrospective study included consecutive patients with resectable BCLC A/B beyond Milan HCC undergoing upfront SR or neoadjuvant therapy. All images were independently evaluated by three blinded radiologists.

View Article and Find Full Text PDF

Photoacoustic tomography (PAT) is a non-destructive, non-ionizing, and rapidly expanding hybrid biomedical imaging technique, yet it faces challenges in obtaining clear images due to limited data from detectors or angles. As a result, the methodology suffers from significant streak artifacts and low-quality images. The integration of deep learning (DL), specifically convolutional neural networks (CNNs), has recently demonstrated powerful performance in various fields of PAT.

View Article and Find Full Text PDF

Preparation of a 6FDA-DAM/ODA Mixed Matrix Membrane Doped with MOFs and Its Application in Gas Separation.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 210009, China.

Mixed matrix membranes (MMMs) can significantly improve gas separation performance, but the type and state of the filler in the membrane matrix are key indicators for the development of MMMs. Therefore, in this work, 6FDA-DAM/ODA (1:1), metal-organic frameworks (MOFs) with different particle sizes (UiO-66 and UiO-66-NH) were synthesized, and then MOFs were doped into 6FDA-DAM/ODA to prepare MMMs. The effects of the dopant materials and their particle sizes on the gas separation performance of the membranes were investigated by testing the permeability of the MMMs to H, CO, CH, and N.

View Article and Find Full Text PDF

The socioecological conditions of Mexican regions are conducive to the spread of vector-borne diseases. Although there are established treatment guidelines for dengue and rickettsiosis, diagnosis is complicated. The objective of this work was to identify epitopes of Rickettsia and dengue virus that could be used in serology screening against vector-borne diseases.

View Article and Find Full Text PDF

The noise exposure levels of workers wearing hearing protective devices (HPDs) depend on ambient noise and the protective effect of hearing protectors. This cross-sectional study aimed to adjust for cumulative noise exposure (CNE) based on the effective protection of hearing protection devices and explore the dose-response relationship between noise-induced hearing loss (NIHL) and adjusted cumulative noise exposure. A questionnaire was used to acquire the basic characteristics and occupational information of noise-exposed workers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!