A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Estimating Probability for Esophageal Obstruction: A Diagnostic Decision Support Tool Applying Machine Learning to Functional Lumen Imaging Probe Panometry. | LitMetric

Background/aims: This study aimed to develop a diagnostic tool using machine learning to apply functional luminal imaging probe (FLIP) panometry data to determine the probability of esophagogastric junction (EGJ) obstruction as determined using the Chicago Classification version 4.0 (CCv4.0) and high-resolution manometry (HRM).

Methods: Five hundred and fifty-seven adult patients that completed FLIP and HRM (with a conclusive CCv4.0 assessment of EGJ outflow) and 35 asymptomatic volunteers ("controls") were included. EGJ opening was evaluated with 16-cm FLIP performed during sedated endoscopy via EGJ-distensibility index and maximum EGJ diameter. HRM was classified according to the CCv4.0 as conclusive disorders of EGJ outflow or normal EGJ outflow (timed barium esophagram applied when required and available). The probability tool utilized Bayesian additive regression treesBART, which were evaluated using a leave-one-out approach and a holdout test set.

Results: Per HRM and CCv4.0, 243 patients had a conclusive disorder of EGJ outflow while 314 patients (and all 35 controls) had normal EGJ outflow. The model accuracy to predict EGJ obstruction (based on leave-one-out/holdout test set, respectively) was 89%/90%, with 87%/85% sensitivity, 92%/97% specificity, and an area under the receiver operating characteristic curve of 0.95/0.97. A free, open-source tool to calculate probability for EGJ obstruction using FLIP metrics is available at https://www.wklytics.com/nmgi/prob_flip.html.

Conclusions: Application of FLIP metrics utilizing a probabilistic approach incorporates the diagnostic confidence (or uncertainty) into the clinical interpretation of EGJ obstruction. This tool can provide clinical decision support during application of FLIP Panometry for evaluation of esophageal motility disorders.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9577577PMC
http://dx.doi.org/10.5056/jnm21239DOI Listing

Publication Analysis

Top Keywords

egj outflow
20
egj obstruction
16
egj
11
decision support
8
machine learning
8
imaging probe
8
flip panometry
8
normal egj
8
flip metrics
8
application flip
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!