A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Specific analysis of highly absorbing nanoporous powder by small-angle X-ray scattering. | LitMetric

Specific analysis of highly absorbing nanoporous powder by small-angle X-ray scattering.

J Appl Crystallogr

Institut de Chimie Séparative de Marcoule, UMR CEA/CNRS/UM2/ENSCM 5257, BP17171, Bagnols-sur-Ceze, 30207, France.

Published: October 2022

The characterization of nanoporous powders of highly absorbing compounds by small-angle X-ray scattering (SAXS) involves overcoming several difficulties before quantitative information related to the porous texture, such as the specific surface and the porous volume, can be derived. In this article, first, the contribution of the grain facet reflectivity and scattering from the bulk of a grain with the density of ThO, a highly absorbing material, were calculated. Microporous ThO powder having micrometric grain size was characterized, in which the scattering signal is predominant. A high-resolution synchrotron instrument was used in order to cover a wider range and minimize the absorption effect, and the results were compared with those obtained using a laboratory X-ray source. Concerning the absorption problem existing with a laboratory X-ray source, a new and robust experimental method was proposed to correctly determine the scattering intensity of the highly absorbing granular samples on an absolute scale. This method allows one to calculate accurately the porous volume and the specific surface via Porod's law and the invariant using a laboratory SAXS instrument. This last result opens new perspectives for the characterization of the volume and the specific surface of highly absorbing actinide oxide powders.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9533747PMC
http://dx.doi.org/10.1107/S1600576722006987DOI Listing

Publication Analysis

Top Keywords

highly absorbing
20
specific surface
12
small-angle x-ray
8
x-ray scattering
8
porous volume
8
laboratory x-ray
8
x-ray source
8
volume specific
8
highly
5
absorbing
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!