AI Article Synopsis

Article Abstract

Background: Physicians who treat patients with lower limb diseases should pay attention not only to the patients' clinical condition but also to their individual needs and expectations. For this purpose, many different questionnaires can be employed. This study aimed to validate the Lower Limb Task Questionnaire (LLTQ), Lower Limb Functional Index (LLFI), and Lower Limb Functional Index-10 (LLFI-10) for their use in Polish conditions and to perform a mutual comparison and analysis of differences in subjective assessments by patients who undergo hip or knee arthroplasty.

Methods: The LLTQ, LLFI, and LLFI-10 were translated into Polish. A total of 103 patients who qualified for hip or knee arthroplasty at a University Hospital in from 2019 to 2021 were included in this study. The patients were asked to complete the Polish versions of the LLTQ, LLFI, LLFI-10, Lower Extremity Functional Scale (LEFS), and Short Form-36 four times - twice before and twice after their surgeries.

Results: The Polish versions of the LLTQ, LLFI, and LLFI-10 had good psychometric properties. One year after surgery, the Cohen's standard response mean revealed high improvement of limb functionality and thus quality of life among all patients. We observed better treatment outcomes among patients who had hip osteoarthritis.

Conclusions: The questionnaires were validated and can be used both in everyday health practice and in further research in Poland.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jos.2022.09.009DOI Listing

Publication Analysis

Top Keywords

lower limb
28
limb functional
16
polish versions
12
lltq llfi
12
llfi llfi-10
12
lower
8
limb
8
limb task
8
task questionnaire
8
functional index-10
8

Similar Publications

Deep venous thrombosis (DVT) represents a significant postoperative complication after artificial femoral head replacement, with the incidence increasing proportionally with patient age. This study aimed to evaluate the effect of early postoperative use of intermittent pneumatic compression devices (IPC), followed by the combined use of low molecular weight heparin (LMWH) after 48 hours, for the prevention of postoperative lower limb DVT in elderly patients undergoing hip arthroplasty. The retrospective study included 100 elderly patients who underwent unilateral femoral head replacement.

View Article and Find Full Text PDF

Fenestrated Anaconda Endograft for the Treatment of Complex Aortic Aneurysms: Systematic Review and Meta-Analysis.

J Endovasc Ther

January 2025

Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, University of Bern, Bern, Switzerland.

Purpose: To perform a systematic review and meta-analysis of the outcomes of Anaconda fenestrated endograft for the treatment of complex abdominal aortic aneurysms (cAAA).

Material And Methods: A systematic search of all the literature reported until May 2024 was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The pooled 30-day mortality rate, technical success rate, reintervention rate as well as bridging stent occlusion rate, and corresponding 95% confidence intervals (CIs) were estimated using fixed or random effect methods.

View Article and Find Full Text PDF

This study investigates the effects of electrical stimulation (EMS) combined with strength training on lower limb muscle activation and badminton jump performance, specifically during the "jump smash" movement. A total of 25 male badminton players, with a minimum of three years of professional training experience and no history of lower limb injuries, participated in the study. Participants underwent three distinct conditions: baseline testing, strength training, and EMS combined with strength training.

View Article and Find Full Text PDF

Objective: This study aimed to investigate the effects of a 12-week self-designed exercise game intervention on the kinematic and kinetic data of the supporting leg in preschool children during the single-leg jump.

Methods: Thirty 5- to 6-year-old preschool children were randomly divided into an experimental group (EG) and a control group (CG). The BTS SMART DX motion capture analysis system was used to collect single-leg jump data before the intervention.

View Article and Find Full Text PDF

Non-Intrusive Monitoring of Vital Signs in the Lower Limbs Using Optical Sensors.

Sensors (Basel)

January 2025

Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal.

Invisible health monitoring is currently a topic of global interest within the scientific community. Sensorization of everyday objects can provide valuable health information without requiring any changes in people's routines. In this work, a feasibility study of photoplethysmography (PPG) acquisition in the lower limbs for continuous and real-time monitoring of the vital signs, including heart rate (HR) and respiratory rate (RR), is presented.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!