Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/s41415-022-5108-7 | DOI Listing |
J Contemp Dent Pract
October 2024
Department of Crown and Bridge, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt.
Aim: To assess hard as well as soft peri-implant tissues within cases having two lost adjacent anterior teeth treated through placing either two implants with two separate crowns or only an implant along with a crown with a cantilever, and evaluating the effect of polyetheretherketone (PEEK) restoration on cantilever design up to 18 months after functional loading.
Materials And Methods: Twenty-seven participants (15 males and 12 females; mean age, 38.6 years; range 20-50 years) with missing two adjacent anterior teeth were treated with implant system (Flotecno implant system, Italy).
Biosens Bioelectron
January 2025
Department of Physics, Virginia Commonwealth University, Richmond, VA, 23284, USA; Institute for Sustainable Energy and Environment, Virginia Commonwealth University, Richmond, VA, 23284, USA. Electronic address:
Wearable devices designed for the somatosensory system aim to provide event-cue feedback electronics and therapeutic stimulation to the peripheral nervous system. This prompts a neurological response that is relayed back to the central nervous system. Unlike virtual reality tools, these devices precisely target peripheral mechanoreceptors by administering specific stimuli.
View Article and Find Full Text PDFJ Prosthodont Res
January 2025
Department of Masticatory Function and Health Science, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
Purpose: To compare the stress distribution in loaded zirconia resin-bonded fixed dental prostheses (RBFDPs) and periodontal tissue using finite element analysis, considering reduced alveolar bone levels and the number of retainers.
Methods: A human skull was micro-CT scanned. Three framework designs were tested: a 2-unit RBFDP using the maxillary left central incisor (#21) as an abutment, another using a canine (#23), and a 3-unit RBFDP using both #21 and #23.
Cureus
November 2024
Department of Removable Prosthodontics, Syrian Arab Republic Damascus University Faculty of Dental Medicine, Damascus, SYR.
Background: Determining the distal cantilever length in All-on-Four (All-on-4) implant-supported prostheses is a major factor in the long-term success of these prostheses. The difference in mechanical properties of materials used in the fabrication of these prostheses, such as polyether ether ketone (PEEK), may have an impact on the determination of the cantilever length that best distributes stress.
Aim: To study the distribution of stress in All-on-4 mandibular prostheses in the bone, implants, and framework according to difference cantilever length in PEEK prosthetic framework using three-dimensional finite element analysis.
J Mech Behav Biomed Mater
December 2024
Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!