Aim: This two-year follow-up study was aimed to evaluate declining crestal bone levels around dental implants in patients rehabilitated with mandibular implant-supported overdentures. A three-dimensional advanced radiographic tool, cone beam computed tomography (CBCT), was utilized as radiographic aid in this study.

Materials & Methods: A total of 15 patients wearing mandibular implants supported overdentures were studied for two years. Randomization and strict inclusion/exclusion criteria were followed during study execution. Complete dentures were fabricated with standard methods, which were later anchored by a bilateral implant in the mandibular jaw. Bone loss at all four surfaces in all studied implants was estimated by the cone beam computed tomography (CBCT) technique. These assessments were done at postoperative follow-up periods of six, 12, 18, and 24 months. Duly signed and informed consent was obtained from all participating patients.

Statistical Analysis And Results: The statistical analysis was completed by the software IBM Corp. Released 2013. IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp. All relevant data was entered into it to be analyzed with suitable statistical tests. Out of all 15 studied patients, 11 were male, and four were female. P-value was very significant for the age range 35-40 years (0.01). In all instances, the lingual surface showed minimum, while the distal surface showed maximum bone loss when seen at all postoperative phases. Grossly, the mean bone loss ranged between 0.14-0.45. P-value was highly significant for the measurements made at the lingual and distal sides of implants (for both B and D positions). A comparison of both study groups by one-way ANOVA confirmed a highly significant p-value for estimations done between the groups (0.001).

Conclusion: Within the limitations of the study, the authors confirmed that crestal bone levels showed a clear decreasing pattern in the postoperative phases. Since these deleterious processes can compromise long-term prosthesis success, operators should consider all these facts while planning to implant an overdenture prosthesis in the lower jaw.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553015PMC
http://dx.doi.org/10.7759/cureus.29044DOI Listing

Publication Analysis

Top Keywords

crestal bone
12
bone levels
12
bone loss
12
two-year follow-up
8
levels dental
8
dental implants
8
implants patients
8
patients rehabilitated
8
cone beam
8
beam computed
8

Similar Publications

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.

View Article and Find Full Text PDF

Dental implant coronal surfaces designed with the primary goal of maintaining crestal bone levels may also promote bacterial adhesion, leading to soft tissue inflammation and peri-implant bone loss. Achieving an optimal surface roughness that minimizes bacterial adhesion while preserving crestal bone is crucial. It is hypothesized that a specific threshold surface roughness value may exist below which, and above which, initial bacterial adhesion does not statistically change.

View Article and Find Full Text PDF

Purpose: This study was performed to introduce, evaluate, and compare various novel assessment protocols designed for straightforward, reliable, and reproducible measurement of alveolar bone levels. These protocols are intended for standardized periodontal assessment and follow-up, utilizing cone-beam computed tomography (CBCT) images and manipulation of Digital Imaging and Communications in Medicine (DICOM) viewer software.

Materials And Methods: Two experienced oral and maxillofacial radiologists developed 5 distinct radiographic measurement protocols.

View Article and Find Full Text PDF

Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.

Materials And Methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)).

View Article and Find Full Text PDF

Introduction: Following tooth extraction, there is comparatively more bone loss at the buccal aspect at 3 months of healing, which may result in 56% bone loss due to resorption of the bucco-facial ridge contour. In the socket shield technique, a tooth is planned for extraction in such a way that the tooth is sectioned in two halves, a palatal section is removed and the facial part is retained.

Materials And Methods: Twenty-six sites, i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!