As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh's criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.460232DOI Listing

Publication Analysis

Top Keywords

high-resolution ptychographic
4
imaging
4
ptychographic imaging
4
imaging enabled
4
enabled high-speed
4
high-speed multi-pass
4
multi-pass scanning
4
scanning coherent
4
coherent diffraction
4
diffraction imaging
4

Similar Publications

Fourier Ptychographic Microscopy (FPM) provides high-resolution imaging and morphological information over large fields of view, while Computational Scattered Light Imaging (ComSLI) excels at mapping interwoven fiber organization in unstained tissue sections. This study introduces Fourier Ptychographic Scattered Light Microscopy (FP-SLM), a new multi-modal approach that combines FPM and ComSLI analyses to create both high-resolution phase-contrast images and fiber orientation maps from a single measurement. The method is demonstrated on brain sections (frog, monkey) and sections from thigh muscle and knee (mouse).

View Article and Find Full Text PDF

We introduce ssc-cdi, an open-source software package from the Sirius Scientific Computing family, designed for memory-efficient, single-node multi-GPU ptychography reconstruction. ssc-cdi offers a range of reconstruction engines in Python version 3.9.

View Article and Find Full Text PDF

A high-performance reconstruction method for partially coherent ptychography.

Ultramicroscopy

December 2024

Shenzhen Key Laboratory of Robotics Perception and Intelligence, and the Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen 518055, China. Electronic address:

Article Synopsis
  • Ptychography is now widely used in microscopy for greater imaging precision but is limited by the coherence of the light sources used.
  • A new universal reconstruction algorithm has been developed that works effectively even with low coherence, improving image quality without needing prior source information.
  • This algorithm enhances existing ptychographic systems, leading to faster and more stable reconstructions, especially beneficial for imaging weakly scattering samples.
View Article and Find Full Text PDF

Fourier Ptychographic Coherent Anti-Stokes Raman Scattering Microscopy with Point-Scanning for Super-Resolution Imaging.

Small Methods

October 2024

Optical Bioimaging Laboratory, Department of Biomedical Engineering, College of Design and Engineering, National University of Singapore, Singapore, 117576, Singapore.

Fourier ptychography (FP) is a high resolution wide-field imaging method based on the extended aperture in the Fourier space, which is synthesized from raw images with varying illumination angles. If FP is extended to coherent nonlinear optical imaging, the resolution could be further improved due to the increase of the cutoff frequency of the synthesized coherent optical transfer function (C-OTF) with respect to the order of nonlinear optical processes. However, there is a fundamental conflict between wide-field FP and nonlinear optical imaging, whereby the nonlinear optical imaging typically requires a focused excitation laser beam with high power density.

View Article and Find Full Text PDF

Three-Dimensional Nanoscale Imaging of SiO2 Nanofiller in Styrene-Butadiene Rubber with High-Resolution and High-Sensitivity Ptychographic X-ray Computed Tomography.

Microsc Microanal

November 2024

International Center for Synchrotron Radiation Innovation Smart (SRIS), Tohoku University, 468-1 Aramaki-Aza-Aoba, Aoba-ku, Sendai 980-8572, Japan.

SiO2 aggregates in styrene-butadiene rubber (SBR) were observed using ptychographic X-ray computed tomography (PXCT). The rubber composites were illuminated with X-rays focused by total reflection focusing mirrors, and the ptychographic diffraction patterns were collected using a CITIUS detector in the range of -75° to +75° angle of incidence. The projection images of the rubber composites were reconstructed with a two-dimensional resolution of 76 nm, and no significant structural changes were observed during the PXCT measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!