The increase of the aging population brings numerous challenges to health and aesthetic segments. Here, the use of laser therapy for dermatology is expected to increase since it allows for non-invasive and infection-free treatments. However, existing laser devices require doctors' manually handling and visually inspecting the skin. As such, the treatment outcome is dependent on the user's expertise, which frequently results in ineffective treatments and side effects. This study aims to determine the workspace and limits of operation of laser treatments for vascular lesions of the lower limbs. The results of this study can be used to develop a robotic-guided technology to help address the aforementioned problems. Specifically, workspace and limits of operation were studied in eight vascular laser treatments. For it, an electromagnetic tracking system was used to collect the real-time positioning of the laser during the treatments. The computed average workspace length, height, and width were 0.84 ± 0.15, 0.41 ± 0.06, and 0.78 ± 0.16 m, respectively. This corresponds to an average volume of treatment of 0.277 ± 0.093 m. The average treatment time was 23.2 ± 10.2 min, with an average laser orientation of 40.6 ± 5.6 degrees. Additionally, the average velocities of 0.124 ± 0.103 m/s and 31.5 + 25.4 deg/s were measured. This knowledge characterizes the vascular laser treatment workspace and limits of operation, which may ease the understanding for future robotic system development.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573018PMC
http://dx.doi.org/10.3390/s22197481DOI Listing

Publication Analysis

Top Keywords

workspace limits
16
limits operation
16
laser treatments
16
laser
8
operation laser
8
treatments vascular
8
vascular lesions
8
lesions lower
8
lower limbs
8
vascular laser
8

Similar Publications

With the decreasing and aging agricultural workforce, fruit harvesting robots equipped with higher degrees of freedom (DoF) manipulators are seen as a promising solution for performing harvesting operations in unstructured and complex orchard environments. In such a complex environment, guiding the end-effector from its starting position to the target fruit while avoiding obstacles poses a significant challenge for path planning in automatic harvesting. However, existing studies often rely on manually constructed environmental map models and face limitations in planning efficiency and computational cost.

View Article and Find Full Text PDF

Objective: Residents interact, collaborate with, and learn from nurses, advanced practice providers, and physicians in multiple specialties. Both positive and negative experiences in the clinical workspace can affect residents' well-being, their ability to learn, and their development into effective, independent physicians. The aim of this study is to evaluate the general surgery resident experience in the nonsurgical clinical learning environment to identify how interactions outside of the operating room affect resident well-being and their ability to learn.

View Article and Find Full Text PDF

Next-generation sequencing RNA fusion panel for the diagnosis of haematological malignancies.

Pathology

November 2024

Department of Haematology, Monash Health, Clayton, Vic, Australia; Department of Diagnostic Genomics, Monash Health, Clayton, Vic, Australia; School of Clinical Sciences, Monash University, Clayton, Vic, Australia. Electronic address:

Haematological malignancies are being increasingly defined by gene rearrangements, which have traditionally been detected by karyotype, fluorescent in situ hybridisation (FISH) or reverse-transcriptase polymerase chain reaction (RT-PCR). However, these traditional methods may miss cryptic gene rearrangements and are limited by the number of gene rearrangements screened at any one time. A next-generation sequencing (NGS) RNA fusion panel is an evolving technology that can identify multiple fusion transcripts in a single molecular assay, even without prior knowledge of breakpoints or fusion partners.

View Article and Find Full Text PDF

Background: Cable-driven continuum manipulators (CDCMs) enable scar-free procedures but face limitations in workspace and control accuracy due to hysteresis.

Methods: We introduce an extensible CDCM with a semi-active mechanism (SAM) and develop a real-time hysteresis compensation control algorithm using a temporal convolution network (TCN) based on data collected from fiducial markers and RGBD sensing.

Results: Performance validation shows the proposed controller significantly reduces hysteresis by up to 69.

View Article and Find Full Text PDF

Current wireless capsule endoscopy (WCE) is limited in the long examination time and low flexibility since the capsule is passively moved by the natural peristalsis. Efforts have been made to facilitate the active locomotion of WCE using magnetic actuation and localization technologies. This work focuses on the motion control of the robotic capsule under magnetic actuation in a complex gastrointestinal (GI) tract environment in order to improve the efficiency and accuracy of its motion in dynamic, complex environments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!