Loop Closure Detection Based on Residual Network and Capsule Network for Mobile Robot.

Sensors (Basel)

School of Mechanical Engineering, Shenyang Ligong University, Shenyang 110159, China.

Published: September 2022

Loop closure detection based on a residual network (ResNet) and a capsule network (CapsNet) is proposed to address the problems of low accuracy and poor robustness for mobile robot simultaneous localization and mapping (SLAM) in complex scenes. First, the residual network of a feature coding strategy is introduced to extract the shallow geometric features and deep semantic features of images, reduce the amount of image noise information, accelerate the convergence speed of the model, and solve the problems of gradient disappearance and network degradation of deep neural networks. Then, the dynamic routing mechanism of the capsule network is optimized through the entropy peak density, and a vector is used to represent the spatial position relationship between features, which can improve the ability of image feature extraction and expression to optimize the overall performance of networks. Finally, the optimized residual network and capsule network are fused to retain the differences and correlations between features, and the global feature descriptors and feature vectors are combined to calculate the similarity of image features for loop closure detection. The experimental results show that the proposed method can achieve loop closure detection for mobile robots in complex scenes, such as view changes, illumination changes, and dynamic objects, and improve the accuracy and robustness of mobile robot SLAM.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573234PMC
http://dx.doi.org/10.3390/s22197137DOI Listing

Publication Analysis

Top Keywords

loop closure
16
closure detection
16
residual network
16
capsule network
16
mobile robot
12
network
9
detection based
8
based residual
8
network capsule
8
robustness mobile
8

Similar Publications

Background: The traditional method of prophylactic loop ileostomy is time-consuming and prone to complications like stoma stenosis, peristomal adhesions, or dermatitis. The aim of this study is to evaluate the clinical application value and potential benefits of a novel approach named linea alba support method (LASM) of prophylactic loop ileostomy via lower abdominal midline incision.

Methods: The clinical data of rectal cancer patients admitted to the General Surgery Department of the First Affiliated Hospital of Xi'an Jiaotong University between January 2021 and December 2023 were retrospectively analyzed.

View Article and Find Full Text PDF

Construction of Loop Polyzwitterion Brushes on PET Sheets via the Chain-End Closure Strategy To Improve Antifouling and Hemocompatible Properties.

Langmuir

January 2025

Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Bio-functional Materials, Department of Materials Science and Engineering, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, P. R. China.

Steric stabilization and lubrication give loop polymer brushes enhanced antifouling properties. In the study, linear zwitterionic poly(NMASMCMS) brushes were first constructed on a poly(ethylene terephthalate) (PET) surface through surface-initiated reversible addition-fragmentation chain-transfer (SI-RAFT) polymerization. The tethered linear brushes on sheets were then thiolated with ethanolamine, followed by oxidation to form loop brushes.

View Article and Find Full Text PDF

Polyethylene Terephthalate (PET) is a petroleum-based plastic polymer that, by design, can last decades, if not hundreds of years, when released into the environment through plastic waste leakage. In the pursuit of sustainable solutions to plastic waste recycling and repurposing, the enzymatic depolymerization of PET has emerged as a promising green alternative. However, the metabolic potential of the resulting PET breakdown molecules, such as the two-carbon (C2) molecule ethylene glycol (EG), remains largely untapped.

View Article and Find Full Text PDF

The ruptured sinus of Valsalva aneurysm (RSOV), a rare but well-recognized clinical entity, is invariably a form of left-to-right shunt due to rupture into right-sided chambers. It causes profound hemodynamic effects, especially when the rupture is acute. Like most other left-to-right shunts, it was only a matter of time before this rare defect also became amenable to transcatheter closure (TCC).

View Article and Find Full Text PDF

Background: A postoperative surgical site infection (SSI) is a prevalent complication after loop ileostomy closure. There are few studies on the risk factors and the development of predictive models for postoperative SSIs. The aim of this study was to develop and validate a nomogram model capable of accurately predicting the occurrence of postoperative SSIs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!