Introduction: The ceramic-on-ceramic couple in total hip arthroplasties (THA) has the advantage of excellent wear resistance and the bioinert nature of its debris. Noise occurring from this friction torque is a common complication, the contributing factors of which are debated. The noise is caused by a lack of lubrication, due in most part to the positioning of the acetabular cup. The study of metal-on-metal couples identified that the calculation of the Contact Patch to Rim (CPR) distance provides information on lubrication defects and also that it is correlated with the wear of metal-on-metal implants. This CPR distance is not recognized to be correlated with the occurrence of noise for the ceramic-on-ceramic couple at a caliber ≤ 36mm. We therefore conducted a retrospective case-control study to assess: 1) The influence of the CPR distance on noise occurrence; 2) Whether other factors associated to noise occurrence exist?
Hypothesis: Our hypothesis was that a low CPR distance was correlated with noise occurrence.
Method: This was a case-control study with 3 controls for each case, analyzing 21 THAs (21 patients) with noise compared to 63 THAs without noise (63 patients) matched for age, sex and body mass index. These patients were taken from a continuous retrospective series of 96 patients for 104 total hip arthroplasties (THA) with a single operator and 4 generation Biolox Delta ceramic-on-ceramic single implant, performed between 2007 and 2012. The calculation of the CPR distance was then performed for both groups using measurements of inclination angles, anteversion angles, and implant data regarding the head/insert contact angle, head/insert diameter and clearance.
Results: At the mean follow-up of 7.1 years±1.2 [5 to 9.6], the mean CPR distance was lower in the noise group 10mm±3.3 [3.8 to 16.4] than in the control group 14.8mm±4.3 [7.3 to 24.4] (p=0.0007). The mean inclination angle was higher in the noise group 45.1°±7.8 [31 to 62] than in the control group 41.2°±7.2 [26 to 56] (p=0.04). The occurrence of noise was independent of anteversion, head caliber, cup diameter, neck length and stem size, and stem type (standard or lateralized).
Conclusion: A low CPR distance was correlated with the occurrence of noises, similarly a steep inclination was correlated with the occurrence of noises.
Level Of Evidence: III; Retrospective case-control study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2022.103438 | DOI Listing |
Prehosp Emerg Care
January 2025
Department of Emergency Medicine, University of Michigan Medical School, Ann Arbor, Michigan.
Objectives: Out-of-hospital cardiac arrest (OHCA) victims receiving defibrillation from an automated external defibrillator (AED) placed early in the chain of survival are more likely to survive. We sought to explore the accuracy of AED pad placement for lay rescuers (LR) and first responders (FR).
Methods: We conducted a secondary analysis of data collected during randomized OHCA simulation trials involving LRs and FRs.
NPJ Prim Care Respir Med
December 2024
Department of Pulmonary and Critical Care Medicine, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, People's Republic of China.
Baduanjin has been shown to be an effective method of exercise for promoting body function in patients with chronic obstructive pulmonary disease (COPD). However, this method is rarely used by rural doctors in rural communities. The aim of this study was to compare the therapeutic effects of Baduanjin exercise with those of conventional pulmonary rehabilitation (CPR) implemented by rural doctors in patients with COPD.
View Article and Find Full Text PDFSci Rep
October 2024
Department of Radiology, Chungnam National University Hospital, 282, Munhwa-ro, Jung-gu, Daejeon, Republic of Korea.
Hum Fertil (Camb)
December 2024
Department of Obstetrics and Gynecology, Nesta Clinic, IVF and Endometriosis Center, Istanbul, Turkey.
Embryo migration is defined as the movement of embryos to implant at the exact site in the endometrial cavity during assisted reproductive technology (ART). We aimed to evaluate the impact of embryo migration on clinical pregnancy (CPR) and live birth rates (LBR) in fresh oocyte donation (OD) cycles. A total of 611 fresh OD cycles was recruited in this prospective cohort study.
View Article and Find Full Text PDFJ Clin Med
August 2024
Department of Emergency Medicine, Seoul Medical Center, Seoul 02053, Republic of Korea.
: Research investigating the optimal compression position for load-distributing bands (LDBs) in treating cardiac arrest is limited This study aimed to determine the optimal LDB position based on body mass index (BMI). : A simulation study was conducted using chest and abdominal computed tomography imaging data collected with patients in the arms-down position. Participants were categorized into three BMI groups: low (<18.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!