A mid-infrared broadband absorber with high visible light transmittance is proposed in this paper. The absorber is composed of layered ITO nanorod arrays with increasing angles fabricated by oblique angle deposition technique. The experimental results show that the average transmittance of the absorber reaches 80% in the 400-800 nm band and the integrated absorption reaches 82.9% in the 3-5 µm band, when the QCM thickness of the first layer of film is 100 nm and the deposition angle θ is 10°, the QCM heights of the second to fifth layers of nanorods are all 330 nm, and their deposition angles are 55°, 68°, 80°, and 87°, respectively. The high transmittance in the visible band is attributed to the gradient of the refractive index. The broadband absorption in the mid-infrared band results from different resonances in the empty cavities with different sizes. Such a simple and large-area absorber has potential applications in window materials and infrared cloaking.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.462894DOI Listing

Publication Analysis

Top Keywords

3-5 µm
8
mid-infrared broadband
8
composed layered
8
layered ito
8
ito nanorod
8
nanorod arrays
8
high visible
8
visible light
8
light transmittance
8
µm mid-infrared
4

Similar Publications

Periacetabular osteotomy (PAO) is a procedure used to treat patients with hip dysplasia. Current literature reports symptomatic hardware removal (HWR) rates of 13.6% following PAO.

View Article and Find Full Text PDF

Context: The natural history and malignant potential of cases classified as atypical adrenal masses (AAMs) are unknown.

Objective: To describe the radiological characteristics and clinical outcomes of AAMs.

Design And Participants: A multicenter retrospective study.

View Article and Find Full Text PDF

Introduction: This study evaluated 10-year results of implanting one iStent trabecular micro-bypass stent during cataract surgery in eyes with open-angle glaucoma (OAG) or ocular hypertension.

Methods: This retrospective, non-randomized study examined 10-year outcomes of iStent trabecular micro-bypass stent implantation with cataract surgery by one surgeon in eyes with OAG [including primary OAG (POAG) and pseudoexfoliative glaucoma (PXG)] or ocular hypertension at a multi-specialty German ophthalmology center. Study visits were conducted preoperatively and at 2.

View Article and Find Full Text PDF

Aims: Recently, a genetic variant-specific prediction model for phospholamban (PLN) p.(Arg14del)-positive individuals was developed to predict individual major ventricular arrhythmia (VA) risk to support decision-making for primary prevention implantable cardioverter defibrillator (ICD) implantation. This model predicts major VA risk from baseline data, but iterative evaluation of major VA risk may be warranted considering that the risk factors for major VA are progressive.

View Article and Find Full Text PDF

Polymeric nanomaterials have seen widespread use in biomedical applications as they are highly tuneable to achieve the desired stimuli-responsiveness, targeting, biocompatibility, and degradation needed for fields such as drug delivery and biosensing. However, adjustments to composition and the introduction of new monomers often necessitate reoptimization of the polymer synthesis to achieve the target parameters. In this study, we explored the use of inverse emulsion polymerization to prepare a library of polymeric nanoparticles with variations in pH and temperature response and examined the impact of overall batch volume and the volume of the aqueous phase on nanoparticle size and composition.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!