A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rigorous calibration of homodyne detection efficiency for continuous-variable quantum key distribution. | LitMetric

We propose a rigorous calibration method for homodyne detection efficiency, which combines all the factors that affect detection efficiency to calibrate together through the actual homodyne detection. With this method, the transmittance converted from electronic noise in the one-time calibration method of the shot noise can be attributed to the detection inefficiency. Thus, a trusted detection noise-free model for continuous-variable quantum key distribution (CV-QKD) can be established, which simplifies the calibration of shot noise while having the same performance as the trusted detection noise model. We demonstrate this calibration method with a balanced detector based on a transimpedance amplifier. Experimental results show that detection efficiency will be overestimated if the integration factor of the detector is overlooked. The overestimation of the detection efficiency leads to an underestimation of modulation variance and excess noise when the modulation variance is monitored by the balanced detector, which opens security loopholes. Our method may prove a necessary method in the calibration of detection efficiency for CV-QKD.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.461680DOI Listing

Publication Analysis

Top Keywords

detection efficiency
24
homodyne detection
12
calibration method
12
detection
10
rigorous calibration
8
continuous-variable quantum
8
quantum key
8
key distribution
8
shot noise
8
trusted detection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!