Coupled Rocking Motion in a Light-Driven Rotary Molecular Motor.

J Org Chem

Stratingh Institute for Chemistry, Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands.

Published: January 2024

Coupled motion is ubiquitous in Nature as it forms the base for the direction, amplification, propagation, and synchronization of movement. Herein, we present experimental proof for the coupling of the rocking motion of a dihydroanthracene stator moiety with the light-induced rotational movement of an overcrowded alkene-based molecular motor. The motor was desymmetrized, introducing two different alkyl substituents to the stator part of the molecular scaffold, resulting in the formation of two diastereomers with opposite axial chirality. The structure of the two isomers is determined with nuclear Overhauser effect spectroscopy NMR and single-crystal X-ray analysis. The desymmetrization enables the study of the coupled motion, that is, rotation and oscillation, by H NMR, findings that are further supported by density functional theory calculations. A new handle to regulate the rotational speed of the motor through functionalization in the bottom half was also introduced, as the thermal barrier for thermal helix inversion is found to be largely dependent on the alkyl substituents and its orientation toward the upper half of the motor scaffold. In addition to the commonly observed successive photochemical and thermal steps driving the rotation of the motor, we find that the motor undergoes photochemically driven rotation in three of the four steps of the rotation cycle. Hence, this result extends the scope of molecular motors capable of photon-only rotary behavior.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10777401PMC
http://dx.doi.org/10.1021/acs.joc.2c01830DOI Listing

Publication Analysis

Top Keywords

rocking motion
8
molecular motor
8
coupled motion
8
alkyl substituents
8
motor
7
coupled rocking
4
motion
4
motion light-driven
4
light-driven rotary
4
molecular
4

Similar Publications

: Colon capsule endoscopy (CCE) is becoming more widely available across Europe, but its uptake is slow due to the need for follow-up colonoscopy for therapeutic procedures and biopsies, which impacts its cost-effectiveness. One of the major factors driving the conversion to colonoscopy is the detection of excess polyps in CCE that cannot be matched during subsequent colonoscopy. The capsule's rocking motion, which can lead to duplicate reporting of the same polyp when viewed from different angles, is likely a key contributor.

View Article and Find Full Text PDF

In a ship rocking environment, muscle activity in different sitting postures may impact passenger balance and stability, thereby aggravating or alleviating symptoms of motion sickness. This study aims to explore the relationship between motion sickness induced by ship rolling and muscle activity in various sitting postures, with the goal of informing the optimization of ship seat designs to enhance passenger comfort. The research focuses on the angle of backrest inclination and head-neck position as key variables.

View Article and Find Full Text PDF

Ultrasonography of the cricoarytenoid joint and its movements.

Auris Nasus Larynx

December 2024

Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Jichi Medical University, Shimotsuke, Tochigi, Japan.

Objective: Ultrasound provides real-time anatomical information and motion. We used ultrasound to image the cricoarytenoid joint and its rotating, rocking, and gliding movements.

Methods: Between March and October 2023, 20 patients (10 males and 10 females) who visited our hospital underwent laryngeal ultrasonography.

View Article and Find Full Text PDF
Article Synopsis
  • The electromagnetic middle-ear implant (MEI) is a new device designed to help with sensorineural and mixed hearing loss, and its effectiveness relies on where the transducer stimulates the ear.
  • Researchers used a human-ear finite element model to evaluate how different stimulation sites (umbo, incus body, incus long process, and stapes) influence the motion of the stapes bone, comparing the results to experimental data.
  • Findings indicate that low and middle frequencies show similar stapes motion with certain stimulation sites compared to normal hearing, while at high frequencies, one site aligns closely with normal hearing responses; additionally, the direction of stimulation affects sound pressure levels differently than motion types.
View Article and Find Full Text PDF
Article Synopsis
  • Total knee arthroplasty (TKA) is a common surgical procedure for patients with severe knee osteoarthritis, especially when non-surgical treatments fail, leading to significant improvements in pain, function, and quality of life.
  • The procedure can use various components (cemented, cementless, or a hybrid) and is generally performed with a focus on mechanical alignment, although newer alignment strategies like gap and kinematic balancing are showing promising results in early studies.
  • The preferred surgical technique for cementless TKA involves a specific patient positioning and incision approach, starting with the application of a thigh tourniquet and a parapatellar incision, ensuring proper alignment and access during the surgery.*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!