Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: This study compared the shaping ability of the Hyflex CM and XP-endo Shaper rotary file systems in curved mesial canals of mandibular molars using micro-computed tomography.
Material And Methods: Seventeen mesial roots of extracted first mandibular molars with two independent mesial canals were scanned before and after root canal preparation with the tested rotatory file systems. Each mesial canal from the same specimen was prepared with one of the two systems. The parameters analyzed were canal centering (transportation) for the cervical, middle, and apical segments, as well as for the entire canal (0-10 mm from the apex); and canal volume increase, canal surface area increase, and unprepared canal walls for two segments, 0 to 4 mm and 0 to 10 mm from the apex.
Results: There was no significant difference between both systems regarding canal centering (transportation), volume increase, and unprepared canal walls for the 0 to 10 mm segment (> 0.05); however, a significant difference was observed for the 0 to 4 mm segment ( <0.01), where the Hyflex CM left 28.46% of unprepared walls and XP-endo Shaper left 13.26%.
Conclusions: The shaping ability of the two tested rotatory file systems in mesial roots of first mandibular molars was similar for all parameters in all the segments evaluated, except for the 0 to 4 mm segment, where XP-endo Shaper left a smaller area of unprepared canal walls than Hyflex CM.