An elaboration of the photonic based sensors is the most promising direction in modern analytical chemistry from the point of view of real clinical applications. The highest sensitivity is demonstrated by sensors based on photonic integrated circuits (PICs). This type of sensor has been recently successfully combined with microfluidics, which decreased the analyte volume for analysis down to microliter units. The most significant disadvantage regarding these photonic sensors is low specificity. One of the methods that could be useful for such type of problem is the layer by layer (LBL) assembly. The peculiarity of a PIC based sensor is the ability to precisely control surface modification by using measurements of a minimum resonance position shift. The bovine serum albumin (BSA) and tannic acid (TA) molecules were selected for LBL assembly because on one side they form a stable LBL assembly film based on hydrogen bonds, while the other side of both TA and BSA molecules can be used for conjugation with target molecules. A microring resonator (MRR) and a Mach-Zehnder interferometer (MZI) based on a silicon nitride platform combined with a microfluidic system were elaborated and used for monitoring the LBL film assembly. Obtained results have a good correlation with measurements carried out by atom force microscopy. Thus, the ability of using PIC based sensors for control of surface modification was demonstrated and can be considered in point-of-care (POC) devices that have a very good perspective for both early pathological state diagnosis and evaluation of treatment efficiency.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.2c03909 | DOI Listing |
ACS Appl Bio Mater
January 2025
Department of Stomatology, Second Affiliated Hospital, Third Military Medical University, Chongqing 400037, P. R. China.
Micro- and nanomorphological modification and roughening of titanium implant surfaces can enhance osseointegration; however, the optimal morphology remains unclear. Laser processing of implant surfaces has demonstrated significant potential due to its precision, controllability, and environmental friendliness. Femtosecond lasers, through precise optimization of processing parameters, can modify the surface of any solid material to generate micro- and nanomorphologies of varying scales and roughness.
View Article and Find Full Text PDFJ Biomed Mater Res A
January 2025
Department of Orthopedics, The Third Affiliated Hospital of Chongqing Medical University, Chongqing, People's Republic of China.
Bone defects are difficult to treat clinically and most often require bone grafting for repair. However, the source of autograft bone is limited, and allograft bone carries the risk of disease transmission and immune rejection. As tissue engineering technology advances, bone replacement materials are playing an increasingly important role in the treatment of bone defects.
View Article and Find Full Text PDFAnal Chem
January 2025
Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, 500 05 Hradec Králové, Czechia.
The retention behavior in supercritical fluid chromatography (SFC) remains a complex and poorly understood phenomenon despite the development of various models to explain retention mechanisms. This study aims to deepen the understanding of retention by investigating three distinct stationary phases: high-strength silica octadecyl (HSS C18 SB), charged surface hybrid pentafluorophenyl (CSH PFP), and porous graphitic carbon (PGC) as a nonsilica-based phase. Three mobile phase compositions, i.
View Article and Find Full Text PDFNanoscale
January 2025
Advanced Batteries Research Center, Korea Electronics Technology Institute, 25, Saenari-ro, Seongnam-si, 13509, Republic of Korea.
The SiO electrode interface is passivated with a SiO layer, which hinders the deposition of an inorganic solid electrolyte interphase (SEI) due to its high surface work function and low exchange current density of electrolyte decomposition. Consequently, a thermally vulnerable, organic-based SEI formed on the SiO electrode, leading to poor cycling performance at elevated temperatures. To address this issue, the SEI formation process is thermoelectrochemically activated.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Solid State Engineering, University of Chemistry and Technology Prague, 166 28 Prague, Czech Republic.
Here, we present surface analysis and biocompatibility evaluation of novel composite material based on graphene oxide traded as BioHastalex. The pristine material's surface morphology and surface chemistry were examined by various analytical methods. The BioHastalex with a thin silver layer was subsequently heat treated and characterized, the impact on the material surface wettability and morphology was evaluated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!