Positive airway pressure (PAP) is the primary treatment of sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. Just as clinicians use pharmacological mechanism of action and pharmacokinetic data to optimize medication therapy for an individual, understanding how PAP works and choosing the right mode and device are critical to optimizing therapy in an individual patient. The first section of this chapter will describe the technology inside PAP devices that is essential for understanding the algorithms used to control the airflow and pressure. The second section will review how different comfort settings including ramp and expiratory pressure relief and modes of PAP therapy including continuous positive airway pressure (CPAP), autotitrating CPAP, bilevel positive airway pressure, adaptive servoventilation, and volume-assured pressure support control the airflow and pressure. Proprietary algorithms from several different manufacturers are described. This chapter derives its descriptions of algorithms from multiple sources including literature review, manufacture publications and websites, patents, and peer-reviewed device comparisons and from personal communication with manufacturer representatives. Clinical considerations related to the technological aspects of the different algorithms and features will be reviewed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/978-3-031-06413-5_18 | DOI Listing |
Forensic Sci Med Pathol
January 2025
Department of Surgical Sciences, University of Rome Tor Vergata, Via Montpellier 1, 00133, Rome, Italy.
Sudden unexpected infant death (SUID) encompasses both explained and unexplained infant fatalities. When a comprehensive investigation yields inconclusive results, the case is classified as sudden infant death syndrome (SIDS). On the other hand, the most frequent non-SIDS diagnoses may be attributed to specific causes of death including a heterogeneous spectrum of conditions and disorders (e.
View Article and Find Full Text PDFSleep
January 2025
Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore.
Study Objectives: We compared mandibular advancement device (MAD) versus CPAP on quality-of-life (QoL) in a prespecified analysis of the CRESCENT trial.
Methods: 220 participants over age 40 with OSA, hypertension, and increased cardiovascular risk from three public hospitals were randomly assigned to MAD or CPAP (1:1). Multi-dimensional QoL questionnaires were administered at baseline, 6 months, and 12 months.
Pulmonology
December 2025
Department of Emergency and Intensive Care, Fondazione IRCCS San Gerardo dei tintori, Monza, Italy.
Background: Non-invasive helmet respiratory support is suitable for several clinical conditions. Continuous-flow helmet CPAP systems equipped with HEPA filters have become popular during the recent Coronavirus pandemic. However, HEPA filters generate an overpressure above the set PEEP.
View Article and Find Full Text PDFMonaldi Arch Chest Dis
January 2025
Department of Respiratory Medicine, N.K.P. Salve Institute of Medical Sciences and Research Center, Lata Mangeshkar Hospital, Nagpur, Maharashtra.
Asthma is a heterogeneous disease characterized by chronic airway inflammation. It is defined by the history of respiratory symptoms such as wheeze, shortness of breath, chest tightness, and cough that vary over time and intensity, together with variable expiratory airflow limitation. A personal history or a family history of allergy is the factor most strongly associated with the development of asthma.
View Article and Find Full Text PDFFront Pediatr
January 2025
The Ritchie Centre, Hudson Institute of Medical Research, Clayton VIC, Australia.
Introduction: As airway liquid is cleared into lung interstitial tissue after birth, the chest wall must expand to accommodate this liquid and the incoming air. We examined the effect of applying external positive and negative pressures to the chest wall on lung aeration in near-term rabbit kittens at risk of developing respiratory distress.
Methods: Rabbit kittens (30 days; term ∼31 days) were randomised into and groups.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!