In single-channel scanning electrochemical cell microscopy, the applied potential during the approach of a micropipette to the substrate generates a transient current upon droplet contact with the substrate. Once the transient current exceeds a set threshold, the micropipette is automatically halted. Currently, the effect of the approach potential on the subsequent electrochemical measurements, such as the open-circuit potential and potentiodynamic polarization, is considered to be inconsequential. Herein, we demonstrate that the applied approach potential does impact the extent of probe-to-substrate interaction and subsequent microscale electrochemical measurements on aluminum alloy AA7075-T73.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.2c02459DOI Listing

Publication Analysis

Top Keywords

single-channel scanning
8
scanning electrochemical
8
electrochemical cell
8
cell microscopy
8
transient current
8
approach potential
8
electrochemical measurements
8
controlling surface
4
surface contact
4
contact oxygen
4

Similar Publications

Susceptibility-weighted imaging (SWI) has been widely used in clinical contexts, in which the speed of acquisition is frequently a critical issue. In this study, we aim to test the feasibility of a deep learning (DL)-based reconstruction method for accelerating SWI acquisition in clinical settings. A total of 61 subjects were consecutively enrolled.

View Article and Find Full Text PDF

Hydrogel-Integrated Heart-on-a-Chip Platform for Assessment of Myocardial Ischemia Markers.

ACS Omega

October 2024

Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul 34752, Turkey.

Article Synopsis
  • The study developed a heart-on-a-chip platform using a single-channel PDMS microchip integrated with a hydrogel scaffold to support cardiomyocyte growth, mimicking human heart conditions.
  • This platform allows for better physiological simulations compared to previous microchip designs by employing 3D cell culture rather than 2D methods to create a more realistic cell microenvironment.
  • The heart-on-a-chip was tested under both normal and low-oxygen conditions to model myocardial ischemia, successfully detecting various biomarkers related to heart conditions, indicating its potential for future biological and clinical applications.
View Article and Find Full Text PDF

Background: EBT-XD film specially designed for high dose verifications such as stereotactic treatments. The dose response of the film can be affected by several factors, the curly nature of the film being one of them. In this study this curly nature of the film was investigated for stereotactic body radiotherapy (SBRT) plan verifications.

View Article and Find Full Text PDF

In this study, we proposed a multiplexed color illumination strategy to improve the data acquisition efficiency of Fourier ptychography microscopy (FPM). Instead of sequentially lighting up one single channel LED, our method turns on multiple white light LEDs for each image acquisition via a color camera. Thus, each raw image contains multiplexed spectral information.

View Article and Find Full Text PDF

A novel HPLC method was developed and validated to determine radiochemical identity, radiochemical purity and chemical purity for the analysis of O-(2-[F]fluoroethyl-l-tyrosine ([F]FET). In this method, an analytical Phenomenex Gemini C18 column was used with an isocratic eluent of 7 % ethanol and 93 % 50 mM potassium phosphate buffer (pH = 6.9).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!