Platelet-Rich Fibrin Progressive Protocol: Third Generation of Blood Concentrates.

J Oral Maxillofac Surg

Department of Oral and Maxillofacial Surgery, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil; Department of Cell Biology, Histology and Embryology, Biomedical Science Institute, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil. Electronic address:

Published: January 2023

Purpose: Platelet-rich fibrin (PRF) has been used in several fields of dentistry to improve tissue healing. However, PRF from glass tubes results in a limited number of small membranes, increasing clinical difficulty and work time. The aim of this study was to evaluate cell and platelet amounts and biomechanical strength of PRF-giant membranes produced from plastic tubes without additives.

Material And Methods: The investigators designed an ex vivo study, to compare 3 different centrifugation protocols for obtaining PRF: 700 × g/12 minutes (leukocyte and PRF [L-PRF]), 350 × g/14 minutes (GM350), and 60-700 × g more than 15 minutes total (progressive PRF [PRO-PRF]). We collected blood samples from 5 volunteers aged 25-54 years, over 3 different time periods (triplicate and paired study). From each venipuncture, 4 mL of blood was collected in vacutainers with ethylenediamine tetraacetic acid (EDTA) and approximately 104 mL in 12 plastic tubes without additives, which were separated into 3 groups, as per the centrifugation protocols (n = 5): L-PRF, GM350, and PRO-PRF. The PRF from the tubes of the same protocol was aspirated and 9 mL were placed in polylactic acid (PLA) forms and 3 mL were placed in a glass receptacle. The membranes from PLA forms were tested for tensile strength and the membranes from glass receptacles were evaluated by histomorphometry, while platelets and leukocytes were counted for those in tubes with EDTA. Statistical analyses were performed using Shapiro-Wilk normality test and then a one-way repeated measures analysis followed by Tukey multiple comparisons test (α < 0.05).

Results: In tensile analyses, PRO-PRF (0.85 ± 0.23 N) showed a significantly higher maximum breaking strength than L-PRF (0.61 ± 0.26 N, P = .01) and GM350 (0.58 ± 0.23 N, P < .01). The histomorphometry revealed no significant statistical difference in cell counts between the groups (P = .52). Furthermore, there was no significant difference between the leukocyte (P = .25) and platelet counts (P = .59) in whole blood between the groups.

Conclusion: The progressive protocol (PRO-PRF) enabled the production of PRF giant membranes with greater tensile strength and adequate cell distribution. Moreover, it allows biomaterial incorporation during production and enables clinical control of membrane thickness and size as per the surgical procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joms.2022.09.002DOI Listing

Publication Analysis

Top Keywords

platelet-rich fibrin
8
plastic tubes
8
centrifugation protocols
8
pla forms
8
prf
6
tubes
5
fibrin progressive
4
progressive protocol
4
protocol third
4
third generation
4

Similar Publications

(1) Background: The aim of this prospective study was to evaluate the efficacy of topical application of leukocyte- and platelet-rich fibrin (L-PRF) membranes for treating chronic cutaneous wounds in dogs. (2) Methods: Chronic wounds unresponsive to conventional treatments were assessed on digital photographs and classified using the Bates-Jensen Wound Assessment Tool (BWAT). Each lesion was treated with L-PRF membranes.

View Article and Find Full Text PDF

Usefulness of serial in vivo imaging to directly assess the role of inflammation in thrombus resolution and organization.

Biochem Biophys Res Commun

January 2025

Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan; Laboratory of Clinical Pharmaceutical Science, Kobe Pharmaceutical University, Kobe, Japan.

Deep vein thrombosis (DVT) remains a significant health problem. Although animal models have provided significant insights into the DVT pathophysiology, time-course assessment in a same animal is technically limited. Recently, we reported a novel murine saphenous DVT model for in vivo visualization of spatiotemporal dynamics of inflammatory cells.

View Article and Find Full Text PDF

Aim: This study aims to evaluate the impact of platelet-rich fibrin (PRF) and platelet-rich plasma (PRP) on pain, swelling, trismus, soft tissue healing and bone regeneration following mandibular third molar extraction.

Material And Methods: A systematic review was conducted from a period of January 2014 to June 2024 using PRISMA guidelines. The search strategy included databases such as Scopus, PubMed, Google Scholar, and Cochrane Central Register of Controlled Trials, using key terms related to "PRF", "PRP", oral surgery, and third molars.

View Article and Find Full Text PDF

Aim: This study intended to comprehend the effects of injectable platelet-rich fibrin (i-PRF) on anchor loss and space closure rates during the retraction phase of orthodontic treatment.

Materials And Methods: Twenty-four participants with malocclusion, necessitating extractions and space closure during orthodontic treatment, were enrolled and divided into two groups ( = 12 participants) group A: the experimental group was administered i-PRF on the maxilla/mandible, while group B: the control group did not. Measurements of the rate of space closure, anchor loss, and salivary enzyme activity were done before retraction (T0), after three weeks (T1), after six weeks (T2), and after nine weeks (T3).

View Article and Find Full Text PDF

Aim: This study aimed to evaluate the impact of a combination of immediate implant placement with maxillary sinus augmentation (MSA) solely using platelet-rich fibrin (PRF) on guided bone regeneration.

Materials And Methods: An interventional before-after (pre-post) study design was used with 30 dental patients (≥18 years of age; 14 males and 16 females) with initial bone heights ranging between 4 and 6 mm. Following the general check-up and the creation of a study model, the planned implant location demonstrated an external right maxilla diameter of more than 5 mm, thereby validating the cone-beam computed tomography (CBCT) radiograph.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!