Filter-based embolic protection device in saphenous vein graft percutaneous intervention: A case report.

Radiol Case Rep

Department of Cardiology and Vascular Medicine, Faculty of Medicine, Universitas Airlangga - Dr. Soetomo General Hospital, Surabaya, Jalan Mayjen Prof. Dr. Moestopo No.6-8, Surabaya 60286, Indonesia.

Published: December 2022

Saphenous vein grafts (SVGs) are commonly used in coronary artery bypass graft (CABG) surgery patients. However, SVGs are prone to degradation and occlusion, resulting in poor long-term patency. Percutaneous coronary intervention (PCI) for SVG has been one of the options to treat SVGs disease despite its challenges. Embolic protection device (EPD) use along with proper stent and medications are considered to minimize complications in this procedure. A 61-year-old man, with 4-vessel coronary artery bypass using SVGs and left internal mammary artery (LIMA) 11 years ago, presented with chest pain for more than 3 months. Coronary angiography showed severe stenosis of the SVG to PDA with two lesions, chronic total occlusion in SVG to OM and LIMA to LAD, with patent SVG to D1. He was admitted for elective PCI using drug-eluting stents and distal embolic filter. There were no problems observed, and the procedure was completed with successful stenting in SVG to PDA without any complications. The patient was discharged on dual-antiplatelet therapy along with his previous medication history. PCI is preferred over repeated CABG in high-risk patients, and EPD should be considered whenever technically possible to minimize the risk of distal embolization and thereby improve outcomes in SVG PCI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9530409PMC
http://dx.doi.org/10.1016/j.radcr.2022.08.103DOI Listing

Publication Analysis

Top Keywords

embolic protection
8
protection device
8
saphenous vein
8
coronary artery
8
artery bypass
8
svg pda
8
svg
6
filter-based embolic
4
device saphenous
4
vein graft
4

Similar Publications

Background Carotid artery stenting is a well-established alternative treatment to carotid endarterectomy for carotid artery stenosis for preventing stroke. This study assessed the procedural and clinical outcomes in patients undergoing carotid artery stenting in a tertiary care center in India. Methods A total of 39 patients underwent carotid artery stenting from January 2022 to December 2023, with different embolic protection devices and carotid stents.

View Article and Find Full Text PDF

Retrieval of Entrapped Embolic Protection Device during Carotid Artery Stenting: A Case Report.

Ann Ital Chir

January 2025

Institute of Central Nervous System Vascular Injury and Repair, Jining Medical Science Research Institute, The First People's Hospital of Jining, 272000 Jining, Shandong, China.

Aim: This study aims to report a rare case of an embolization protection device (EPD) entrapment during Carotid Artery Stent (CAS) and to discuss the management strategy, including open surgery and concurrent carotid endarterectomy (CEA).

Case Presentation: A 71-year-old female presented with left limb weakness and unclear speech following CAS. Imaging revealed a new cerebral infarction and right internal carotid artery stenosis.

View Article and Find Full Text PDF

The protective effect of serum antibodies in preventing SARS-CoV-2 virus entry into cardiac muscle.

Physiol Res

December 2024

Laboratory of Neurobiology and Molecular Psychiatry, Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic.

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been associated with significant cardiovascular complications, including myocardial infection and pulmonary embolism. This study aims to elucidate the relationship between the presence of SARS-CoV-2 RNA in the myocardium of the left ventricle and the levels of IgG and IgM antibodies against the SARS-CoV-2 virus in deceased COVID-19 patients. We conducted a post-mortem examination on 91 individuals who succumbed to COVID-19-related complications.

View Article and Find Full Text PDF

Coil embolization of cerebral aneurysms often encounters challenges in achieving complete filling of the aneurysm sac due to complex shapes and hemodynamic factors, frequently resulting in the formation of a residual cavity (RC) at the aneurysm neck. The hemodynamic mechanisms underlying RC formation and growth, however, remain poorly understood. Computational fluid dynamics (CFD) analysis, combined with silent MRA free from contrast agents and metal artifacts, offers a promising approach to elucidate these mechanisms, potentially enhancing the clinical management of cerebral aneurysms post-coiling.

View Article and Find Full Text PDF

The PERFORMANCE II Trial: A Prospective Multicenter Investigation of a Novel Carotid Stent System.

JACC Cardiovasc Interv

December 2024

Department for Angiology, Brandenburg Medical School Theodor Fontane, Campus Clinic Brandenburg, Center for Internal Medicine I, Berlin, Germany; Department of Angiology, Sankt-Gertrauden-Krankenhaus, Berlin, Germany.

Background: Several randomized clinical trials have shown that the composite endpoint of death, stroke, and myocardial infarction (MI) is equivalent between carotid artery stenting and carotid endarterectomy. However, the risk of minor stroke has been consistently higher with carotid artery stenting.

Objectives: The authors sought to evaluate the safety and effectiveness of a novel carotid stent system comprised of a stent, an adjustable integrated embolic filter and a postdilation balloon, in patients at elevated risk for adverse events from carotid endarterectomy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!