Purpose: To evaluate the repeatability of macular hole (MH) diameter measurement on en face slab optical coherence tomography (OCT) reflectance images and assess its potential to predict visual acuity (VA).
Methods: We enrolled 27 eyes with full-thickness MHs in this study. Preoperative en face slab OCT reflectance images were obtained. Image binarization, ellipse approximation, and uncorrected measurement of minimum diameter, min(ef_uc), and maximum diameter, max(ef_uc), were performed using ImageJ. In addition, magnification-corrected diameters were calculated as min(ef) and max(ef) using the Littman and modified Bennett formulas. Spectral-domain OCT horizontal images were used as the conventional method for the analysis: min(conv) and max(conv). The inter-rater reliability of the method was evaluated by calculating the intraclass correlation coefficient (ICC). The following relationships were analyzed: (1) between logMAR VA and min(ef_uc), min(ef), and min(conv); and (2) between logMAR VA and max(ef_uc), max(ef), and max(conv).
Results: The min(ef) and max(ef) values were 439.4 ± 240.5 µm and 720.7 ± 346.1 µm, respectively. The ICC values were 0.985 and 0.999 for min(ef) and max(ef), and 0.885 and 0.909 for min(conv) and max(conv), respectively. Multivariate analysis suggested that min(ef), but not min(ef_uc) or min(conv), was associated with pre- and postoperative logMAR VA. Furthermore, max(ef), but not max(ef_uc) or max(conv), was also closely correlated with pre- and postoperative logMAR VA.
Conclusions: The MH diameter measured by our method is highly reproducible and closely associated with VA compared to that measured by the conventional method.
Translational Relevance: The MH diameter measured by this modality might serve as an accurate biomarker to predict visual function in eyes with MH.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554266 | PMC |
http://dx.doi.org/10.1167/tvst.11.10.13 | DOI Listing |
Invest Ophthalmol Vis Sci
January 2025
Department of Ophthalmology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Purpose: A projection-resolved optical coherence tomography angiography (PR-OCTA) algorithm with slab-specific strategy was applied in polypoidal choroidal vasculopathy (PCV) to differentiate between polyp and branching vascular network (BVN) and improve polyp detection by en face OCTA.
Methods: Twenty-nine participants diagnosed with PCV by indocyanine green angiography (ICGA) and 30 participants diagnosed with typical neovascular age-related macular degeneration (nAMD) were enrolled. Polyps were classified into three categories after using the slab-specific PR algorithm.
Ophthalmol Sci
October 2024
Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida.
Purpose: Spectral-domain OCT angiography (SD-OCTA) scans were used in an algorithm developed for swept-source OCT angiography (SS-OCTA) scans to determine if SD-OCTA scans yielded similar results for the measurement of hyperreflective foci (HRF) in intermediate age-related macular degeneration (iAMD).
Design: Retrospective study.
Participants: Forty eyes from 35 patients with iAMD.
Microcirculation
January 2025
Eye Research Center, The Five Senses Health Institute, Moheb Kowsar Hospital, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Purpose: To assess the colocalization of ellipsoid zone (EZ) disruption with nonperfusion in choriocapillaris (CC), retinal superficial capillary plexus (SCP), and deep capillary plexus (DCP) in diabetic patients using en face optical coherence tomography (OCT) and OCT angiography (OCTA).
Methods: Macular OCT and OCTA scans (3 × 3 mm) of 41 patients with diabetic retinopathy were obtained using an RTVue XR Avanti instrument. After correcting the shadow artifacts, EZ integrity was assessed in the en face OCT slab using the Gaussian mixture model clustering method compared with the corresponding EZ en face OCT of 11 age-matched normal patients.
Materials (Basel)
October 2024
School of Metallurgical and Ecological Engineering, University of Science and Technology Beijing, No. 30 Xueyuan Road, Haidian District, Beijing 100083, China.
Based on a physical water model with a scaling factor of 0.5 and a coupled flow-heat transfer-solidification numerical model, this study investigates the influence of the submerged entry nozzle (SEN) depth on the mold surface behavior, slag entrapment, internal flow field, temperature distribution, and initial solidification behavior in slab casting. The results indicate that when the SEN depth is too shallow (80 mm), the slag layer on the narrow face is thin, leading to slag entrapment.
View Article and Find Full Text PDFAm J Ophthalmol
February 2025
Moran Eye Center, University of Utah, Salt Lake City, Utah, USA (M.F., M.S.S.S.-V., O.T.); Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA (G.H., G.G., P.J.R., O.T.); Department of Ophthalmology, Tel Aviv Medical Center, University of Tel Aviv, Tel Aviv, Israel (O.T.).. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!