A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Doppler study of portal vein and renal venous velocity predict the appropriate fluid response to diuretic in ICU: a prospective observational echocardiographic evaluation. | LitMetric

Background: Fluid overload and venous congestion are associated with morbi-mortality in the ICU (intensive care unit). Administration of diuretics to correct the fluid balance is common, although there is no strong relationship between the consequent fluid loss and clinical improvement. The aim of the study was to evaluate the ability of the portal pulsatility index, the renal venous impedance index, and the VEXUS score (venous ultrasound congestion score) to predict appropriate diuretic-induced fluid depletion.

Methods: The study had a prospective, observational, single-center observational design and was conducted in a university-affiliated medico-surgical ICU. Adult patients for whom the clinician decided to introduce loop diuretic treatment were included. Hemodynamic and ultrasound measurements (including the portal pulsatility index, renal venous impedance index and VEXUS score) were performed at inclusion and 2 hours after the initiation of the diuretics. The patients' characteristics were noted at inclusion, 24 h later, and at ICU discharge. The appropriate diuretic-induced fluid depletion was defined by a congestive score lower than 3 after diuretic fluid depletion. The congestive score included clinical and biological parameters of congestion.

Results: Eighty-one patients were included, and 43 (53%) patients presented with clinically significant congestion score at inclusion. Thirty-four patients (42%) had an appropriate response to diuretic-induced fluid depletion. None of the left- and right-sided echocardiographic parameters differed between the two groups. The baseline portal pulsatility index was the best predictor of appropriate response to diuretic-induced fluid depletion (AUC = 0.80, CI:0.70-0.92, p = 0.001), followed by the renal venous impedance index (AUC = 0.72, CI 0.61-0.84, p = 0.001). The baseline VEXUS score (AUC of 0.66 CI 0.53-0.79, p = 0.012) was poorly predictive of appropriate response to diuretic-induced fluid depletion.

Conclusion: The portal pulsatility index and the renal venous impedance index were predictive of the appropriate response to diuretic-induced fluid depletion in ICU patients. The portal pulsatility index should be evaluated in future randomized studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9535945PMC
http://dx.doi.org/10.1186/s13054-022-04180-0DOI Listing

Publication Analysis

Top Keywords

diuretic-induced fluid
24
renal venous
20
portal pulsatility
20
fluid depletion
20
venous impedance
16
appropriate response
16
response diuretic-induced
16
pulsatility renal
12
vexus score
12
fluid
11

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!