Aim: To study and systematize the complaints of patients with removable prostheses, paying attention to the clinical manifestation of the torus and its sensitivity, and to determine the effectiveness of the use of two-layer bases in removable prosthetics.

Methods: In the clinic of orthopedic dentistry, 104 people were examined and received orthopedic treatment, including 37 patients in the comparison group. The main number of patients up to 55.3, complained of poor fixation and violation of the chewing process. In order to improve the functional efficiency of the removable prosthesis, two-layer bases using soft linings, Gossil (Russia), Furji (Japan), and Mucopren (Germany), are proposed. Clinical and laboratory studies were conducted (Estesmary, gattingeri, physico-mechanical studies of soft linings). The effectiveness of using soft pads in removable prosthetics is shown. The conducted research allowed creating a clinical classification of the torus depending on the pain sensitivity of the oral mucosa-type I-painless torus, type II-moderately painful, and type III-painful when touched. The features of the technology for manufacturing two-layer bases for type II and type III of torus are recommended.

Results: It was found that 47.9% of patients in the comparison group and 55.3% of those examined in the main group complained about impaired chewing and poor fixation of dentures on the upper and lower jaws, depending on the condition of oral tissues. The patients did not always objectively assess the condition of their dentures. Patients complained about lack of stabilization, poor-quality dentures, and the need to replace the old denture with a new one in 13.8% of cases in the control group and 31.9% in the main group of patients examined.

Conclusion: In the case of removable denture wearers with a total lack of teeth, there were 55.3% complaints of chewing disorders and poor fixation of dentures, and in the case of partially removable denture wearers, the greatest number of complaints of clasp fixation disorders were found in 42.1% of cases. Physico-mechanical study of soft linings from different countries, Gossil (Russia), Fuji (Japan), Mukopren (Germany), showed their effectiveness and the possibility of their use orthopedic dentistry.

Download full-text PDF

Source
http://dx.doi.org/10.47750/jptcp.2022.939DOI Listing

Publication Analysis

Top Keywords

two-layer bases
16
poor fixation
12
soft linings
12
clinical classification
8
classification torus
8
effectiveness two-layer
8
bases removable
8
orthopedic dentistry
8
patients comparison
8
comparison group
8

Similar Publications

Aim: To study and systematize the complaints of patients with removable prostheses, paying attention to the clinical manifestation of the torus and its sensitivity, and to determine the effectiveness of the use of two-layer bases in removable prosthetics.

Methods: In the clinic of orthopedic dentistry, 104 people were examined and received orthopedic treatment, including 37 patients in the comparison group. The main number of patients up to 55.

View Article and Find Full Text PDF

Although its mesomorphic properties have been studied for many years, only recently has the molecule of life begun to reveal the true range of its rich liquid crystalline behavior. End-to-end interactions between concentrated, ultrashort DNA duplexes-driving the self-assembly of aggregates that organize into liquid crystal phases-and the incorporation of flexible single-stranded "gaps" in otherwise fully paired duplexes-producing clear evidence of an elementary lamellar (smectic-A) phase in DNA solutions-are two exciting developments that have opened avenues for discovery. Here, we report on a wider investigation of the nature and temperature dependence of smectic ordering in concentrated solutions of various "gapped" DNA (GDNA) constructs.

View Article and Find Full Text PDF

Objective: The aim of the research was to study the dynamics of the microbiota's features of oral mucosal membrane during orthopedic rehabilitation of patients with removable dentures which has an obturating part with two-layer bases.

Patients And Methods: Materials and methods: To achieve this goal, our bacteriological examination of oral cavity mucosa was performed for 25 patients with partial adentia of the upper jaw and defect of hard palate and alveolar process.

Results: Results and conclusions: Of the conducted studies indicate significant shifts in the qualitative and quantitative composition of microbiocenosis in the oral cavity in patients with partial adenia of the upper jaw and a defect of hard palate and alveolar process due to representatives of moraksel, enterobacteria (representatives of the kinds Klebsiella and E.

View Article and Find Full Text PDF

RIFRAF: a frame-resolving consensus algorithm.

Bioinformatics

November 2018

Department of Medicine, University of California San Diego, La Jolla, CA, USA.

Motivation: Protein coding genes can be studied using long-read next generation sequencing. However, high rates of indel sequencing errors are problematic, corrupting the reading frame. Even the consensus of multiple independent sequence reads retains indel errors.

View Article and Find Full Text PDF

Our investigation of one-photon absorption (OPA) and nonlinear optical (NLO) properties such as two-photon absorption (TPA) of silver trimer intercalated in DNA based on TDDFT approach allowed us to propose a mechanism responsible for large TPA cross sections of such NLO-phores. We present a concept that illustrates the key role of quantum cluster as well as of nucleotide bases from the immediate neighborhood. For this purpose, different surroundings consisting of guanine-cytosine and adenine-thymine such as (GCGC) and (ATAT) have been investigated that are exhibiting substantially different values of TPA cross sections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!