Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
BACKGROUND Use of drug-coated balloons (DCB) is an important research topic. Many companies are quickly developing new, cutting-edge technologies and means to deliver drugs. Moreover, interest is growing in use of sirolimus-coated balloons, a promising technology in the "leaving nothing behind" era. This, in combination with interest in lesion preparation and intravascular imaging, creates a promising future for DCB for years to come. CASE REPORT A 72-year-old patient presented with NSTEMI. Coronary angiography showed a subtotal stenosis of the right coronary artery (RCA). PCI was performed on the native RCA and, given the patient's failure to adhere to the drug regimen, he was treated with a metal-free PCI strategy. After using a novel lesion preparation technique with cutting balloon and high-pressure non-compliant balloon, a novel Sirolimus DCB was used. Final angiography and OCT run showed good luminal gain despite diffuse dissections. To assess vascular healing, we performed coronary angiography 5 weeks later, which demonstrated an excellent result, with absence of residual dissection and further luminal gain compared to the index procedure. CONCLUSIONS The use of a novel lesion preparation technique (cutting balloon and high-pressure highly non-compliant balloon) in combination with guidance by intravascular imaging and the use of a new sirolimus-coated balloon may attract attention in the interventional cardiology community and stimulate discussion on lesion preparation and use of drug-coated balloons.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9552860 | PMC |
http://dx.doi.org/10.12659/AJCR.936950 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!