Aim of this study was to examine the accuracy of widely used conventional radiography-based (2D) neck-shaft angle measurements compared to 3D reconstruction. In our retrospective study, EOS 2D/3D images of 156 patients (312 limbs) were selected from our database (4-16 years old: 6 girls and 6 boys/year), where no pathology was revealed. Using the 2D modality of the EOS method neck-shaft angle was measured using the "biggest diameter" and "circle fitting" techniques to define the femoral neck axis and 1/3, 1/2 and full femur to determine the femoral shaft axis. EOS 3D reconstructions of same images were also performed and a comparison of 2D and 3D results was made. We did not find any significant difference between accuracy of the four examined 2D methods, although the deviation between 2 and 3D results was considerable (average difference: 5.11-5.58°, p < 0,001). In 31% of the cases, difference was more than 10°. Only femoral torsion showed significant influence on the difference (correlation coefficient: 0.380, p < 0.001). We did not find a clinically significant difference between the examined 2D methods, although their accuracy was highly questionable compared to 3D results. We suggest using any 3D imaging method for surgical planning and in uncertain cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9529964PMC
http://dx.doi.org/10.1038/s41598-022-20832-1DOI Listing

Publication Analysis

Top Keywords

neck-shaft angle
12
accuracy conventional
8
conventional radiography-based
8
angle measurement
4
measurement children
4
children accuracy
4
radiography-based methods
4
methods compared
4
compared reconstructions
4
reconstructions aim
4

Similar Publications

Purpose: Previous studies have shown that subtrochanteric femoral fractures treated with intramedullary nails might lead to varus-procurvatum malalignment. Similar results have been reported when using antegrade intramedullary lengthening nails (ILNs). The purpose of our study is to examine if antegrade telescoping intramedullary lengthening nails lead to varus-procurvatum malalignment of the proximal femur and what are possible predictors of that shift.

View Article and Find Full Text PDF

Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.

Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.

View Article and Find Full Text PDF

Effective surgical planning is crucial for maximizing patient outcomes following complex orthopedic procedures such as proximal femoral osteotomy. In silico simulations can be used to assess how surgical variations in proximal femur geometry, such as femur neck-shaft and anteversion angles, affect postoperative system mechanics. This study investigated the sensitivity of femur mechanics to postoperative neck-shaft angles, anteversion angles, and osteotomy contact areas using patient-specific finite element analysis informed by neuromusculoskeletal models.

View Article and Find Full Text PDF

Background: Sequential soft tissue releases are utilized in direct anterior approach (DAA) total hip arthroplasty (THA) as incomplete femoral exposure may lead to complications. This study identifies patient-specific parameters associated with soft tissue releases required for femoral exposure.

Methods: A retrospective review was conducted on 133 patients (150 hips) who underwent primary THA via DAA with a single surgeon.

View Article and Find Full Text PDF

Background: Hip morphology variations, particularly in femoral neck shaft angle (NSA) and iliac wing width (IWW), have been associated with gluteal tendinopathy. However, the biomechanical implications of these morphological differences on gluteal muscle function are not well understood. This study investigates how NSA and IWW influence gluteal muscle forces, moment arms, and estimated tendon loads during walking, aiming to provide insights into the potential biomechanical pathways that may contribute to altered lateral hip loading patterns.

View Article and Find Full Text PDF