Continuous measurement of die wall pressure in a rotary tablet machine.

Int J Pharm

Department of Chemical Engineering, Osaka Metropolitan University, 1-1, Gakuen-cho, Naka-ku, Sakai, Osaka 599-8531, Japan.

Published: November 2022

In the pharmaceutical industry, tablets are manufactured using rotary tableting machines. Recently, die wall pressure in a single-punch press was measured to understand the compaction mechanism and predict tableting failure. However, die wall pressure measurements in rotary tableting machines have not been studied. Two challenges exist in measuring die wall pressure in these machines, viz. (i) lack of space inside the machine to set up the measurement equipment and (ii) difficulty in installing wired measurement hardware because the die rotates with the rotary plate. This study aimed to continuously measure die wall pressure in a rotary tableting machine and investigate the effect of high compression speed on die wall pressure. Die wall pressure at tableting speeds of up to 140 mm/s was successfully determined using a wireless telemeter. Residual die wall pressure for plastic materials was strongly dependent on the tableting speed, although the tableting speed affected the maximum die wall pressure minimally. This novel measurement technique can be used to study the effect of tableting speed on die wall pressure, which can be applied in solving the problems of capping and lamination during tablet production.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2022.122251DOI Listing

Publication Analysis

Top Keywords

die wall
40
wall pressure
40
rotary tableting
12
tableting speed
12
die
11
wall
10
pressure
10
pressure rotary
8
tableting
8
tableting machines
8

Similar Publications

Breast cancer outcomes after skin- and nipple-sparing mastectomy in BRCA pathogenic mutation carriers versus non-BRCA carriers.

Radiother Oncol

January 2025

School of Medicine, Tel-Aviv University, Tel-Aviv, Israel; Radiation Unit, Sheba Medical Center, Tel-Hashomer, Ramat-Gan, Israel; GROW-School for Oncology and Developmental Biology, Maastricht University, Maastricht, the Netherlands. Electronic address:

Unlabelled: Our previous study on BRCA breast cancer carriers disclosed a high local recurrence (LR) rate in patients who underwent skin sparing (SSM) or nipple sparing mastectomy (NSM) without postoperative radiation therapy (RT), compared to breast conservation surgery or mastectomy with RT. The current study compares the LR rates in BRCA versus non BRCA carriers after SSM/NSM in relation the receipt of RT.

Methods: The study was approved by the institutional ethics committee.

View Article and Find Full Text PDF

Objective: Removal of a transcutaneous osseintegrated endo-fix stem (ESKA Orthopaedic, Lübeck, Germany) following a fatigue fracture of the implant, whilst protecting the residual femur bone to allow transcutaneous osseointegrated prosthesis system (TOPS) reimplantation.

Indications: A patient's request for a further TOPS implantation following a fatigue fracture of a circular osseointegrated implant stem.

Contraindications: Impending destruction of the bone tube through mobilisation of the femoral implant stem with insufficient thickness of the cortical wall (< 2-3 mm).

View Article and Find Full Text PDF

[Spontaneous craniocervical dissection].

Radiologie (Heidelb)

January 2025

Klinik für diagnostische und interventionelle Neuroradiologie, Universitätskliniken des Saarlandes, Kirrberger Str., 66421, Homburg Saar, Deutschland.

Performance: Spontaneous dissections of the cerebral arteries are among the leading causes of stroke in young adults. They result from hemorrhage into the outer layers of the arterial wall, which can lead to stenosis or even complete vessel occlusion. Clinical presentations vary, ranging from localized pain to cerebral ischemic complications.

View Article and Find Full Text PDF

[Trauma of the midface : Symptoms, diagnostics and treatment].

Radiologie (Heidelb)

January 2025

Klinik für Hals‑, Nasen- und Ohrenheilkunde, Universitätsklinikum Freiburg, Freiburg, Deutschland.

Midface fractures present a clinical challenge in otorhinolaryngology due to their often complex injury pattern and nonspecific symptoms. Precise diagnostics, including differentiated imaging procedures, are required. Interdisciplinary consultation between otorhinolaryngology, maxillofacial surgery, neurosurgery, and ophthalmology is often necessary.

View Article and Find Full Text PDF

The high-pressure die-casting process can effectively manufacture aluminium alloy castings with complex shapes and thin wall thicknesses. However, due to the complex flow characteristics of the liquid metal during the mould-filling process, there are significant differences in the mechanical properties of different parts of the casting. This paper analyses the effect of the high-speed ram transition position on porosity and mechanical properties of Al-Si-Mn-Mg aluminium alloys in the high-pressure die-casting (HPDC) process, comparing the 1160 mm and 1200 mm positions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!