In real-world scene perception, human observers generate sequences of fixations to move image patches into the high-acuity center of the visual field. Models of visual attention developed over the last 25 years aim to predict two-dimensional probabilities of gaze positions for a given image via saliency maps. Recently, progress has been made on models for the generation of scan paths under the constraints of saliency as well as attentional and oculomotor restrictions. Experimental research demonstrated that task constraints can have a strong impact on viewing behavior. Here, we propose a scan-path model for both fixation positions and fixation durations, which include influences of task instructions and interindividual differences. Based on an eye-movement experiment with four different task conditions, we estimated model parameters for each individual observer and task condition using a fully Bayesian dynamical modeling framework using a joint spatial-temporal likelihood approach with sequential estimation. Resulting parameter values demonstrate that model properties such as the attentional span are adjusted to task requirements. Posterior predictive checks indicate that our dynamical model can reproduce task differences in scan-path statistics across individual observers. (PsycInfo Database Record (c) 2023 APA, all rights reserved).

Download full-text PDF

Source
http://dx.doi.org/10.1037/rev0000379DOI Listing

Publication Analysis

Top Keywords

scan-path model
8
task
6
model
5
dynamical scan-path
4
model task-dependence
4
task-dependence scene
4
scene viewing
4
viewing real-world
4
real-world scene
4
scene perception
4

Similar Publications

Effect of scan path on accuracy of complete arch intraoral scan.

J Adv Prosthodont

December 2024

Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.

Purpose: This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.

Materials And Methods: A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner.

View Article and Find Full Text PDF

Different tests measure text comprehension, including the cloze gap-filling test, often used for language learning. Different studies hypothesized cognitive strategies in this type of test and their relationship with working memory and performance. However, no study investigated the cloze test, working memory, and possible cognitive strategies, while performing the test.

View Article and Find Full Text PDF

Purpose: To update data on the transfer accuracy of digital implant impressions by using a coordinate-based analysis, latest intraoral scanners (IOSs) were investigated in an established clinical close model set-up.

Materials And Methods: An implant master model (IMM) of the maxilla with four implants in the posterior area (#14/#24 and #16/#26) and a reference cube was scanned with four different IOS (i700 (Medit), Primescan (Dentsply Sirona), Trios 4 and Trios 5 (3Shape) ten times each. Datasets were compared with a reference dataset of IMM that was generated with x-ray computed tomography in advance.

View Article and Find Full Text PDF

Effect of a calibration aid and the intraoral scanner on the registration of a partially edentulous maxilla: An in vitro study.

J Prosthet Dent

March 2024

Assistant Professor, Department of Prosthetic Dentistry, Heidelberg University Hospital, University of Heidelberg, Heidelberg, Germany. Electronic address:

Statement Of Problem: Precise data are a prerequisite for accurately fitting restorations. Therefore, intraoral scanners have to be reliable. Data on differences between the same model of intraoral scanning systems are lacking.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!