A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of body temperature on the cyclic fatigue resistance of the nickel-titanium endodontic instruments: A systematic review and meta-analysis of studies. | LitMetric

AI Article Synopsis

  • The systematic review aimed to analyze how body temperature affects the cyclic fatigue resistance of nickel-titanium (NiTi) endodontic instruments compared to room temperature.
  • Twenty-one studies were included in the review, and a meta-analysis of six studies showed that NiTi instruments had significantly lower fatigue resistance at body temperature (35°C) than at room temperature (20°C-25°C).
  • The findings suggest that cyclic fatigue tests for these dental instruments should be conducted at simulated body temperature for more accurate results.

Article Abstract

Aim: The aim of this systematic review was to compare the effect of body temperature (I) on the cyclic fatigue resistance (O) of nickel-titanium (NiTi) endodontic instruments (P) to that of room temperature (C).

Methods: The study was registered in the PROSPERO database (CRD42020204286). A systematic search in PubMed, Scopus, Web of Science, Google Scholar, and OpenGrey was conducted in English until December 31, 2021. studies comparing the cyclic fatigue resistance of NiTi instruments at the body (35°C ± 2°C) and room temperature (20°C-25°C) were included. Eligible studies were evaluated for risk of bias and meta-analyzed to estimate the effects.

Results: Twenty-one studies out of 347 met the criteria for inclusion. The meta-analysis included six studies ( = 215) with comparative study parameters. The overall effect sizes (5.49; 95% confidence interval [CI]: 4.04-6.93) were significantly different ( < 0.001), indicating that the mean values at room temperature were significantly ( < 0.001) higher. The effect sizes for full rotary motion (standardized mean difference [SMD]: 4.80; 95% CI: 3.04-6.56) and reciprocating motion (SMD: 6.37; 95% CI: 3.63-9.11) were not significantly different ( = 0.346). Heterogeneity was high ( = 94%). Sensitivity analysis revealed that the SMD values were not significantly different ( > 0.05) from the overall effect size, indicating that none of the studies had an effect on the overall effect size.

Conclusions: Within the limitation of the study, the cyclic fatigue resistance of heat-treated NiTi endodontic files is significantly reduced at body temperature when compared to room temperature. Cyclic fatigue testing should be conducted at simulated body temperature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520645PMC
http://dx.doi.org/10.4103/jcd.jcd_55_22DOI Listing

Publication Analysis

Top Keywords

cyclic fatigue
20
body temperature
16
fatigue resistance
16
room temperature
16
temperature cyclic
12
resistance nickel-titanium
8
endodontic instruments
8
systematic review
8
niti endodontic
8
temperature
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!