Introduction: Both coil and hook-wire localization techniques are commonly employed prior to video-assisted thoracic surgery (VATS) resection in patients with lung nodules (LNs), but the relative advantages of each remain uncertain.

Aim: This meta-analysis was performed to explore the relative safety and efficacy of coil localization (CL) and hook-wire localization (HWL) for patients with LNs.

Material And Methods: The PubMed, Embase, Cochrane Library, Wanfang, and CINK databases were searched to identify relevant studies published as of February 2022, after which pooled analyses of study outcomes were conducted.

Results: In total, 8 studies met the inclusion criteria for the present meta-analysis. Successful localization rates were higher for the CL group relative to the HWL group (p = 0.0001). The CL group additionally exhibited significantly lower pooled total complication, pneumothorax, and lung hemorrhage rates relative to the HWL group (p = 0.01, p = 0.0001, p = 0.0009). Pooled duration of localization, VATS procedure duration, and wedge resection duration values were comparable in both groups (p = 0.69, p = 0.16, p = 0.76), as were chest pain scores (p = 0.06). When specifically analyzing the subset of patients with ground-glass LNs, pooled pneumothorax rates were significantly lower in the CL group relative to the HWL group (p = 0.03). Significant publication bias was detected with respect to rates of lung hemorrhage (Egger test, p = 0.029), but was not evident for other analyzed variables.

Conclusions: These results suggest that the coil-based localization of LNs before VATS resection is safer and more effective than hook-wire localization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9511916PMC
http://dx.doi.org/10.5114/wiitm.2022.116396DOI Listing

Publication Analysis

Top Keywords

hook-wire localization
16
relative hwl
12
hwl group
12
coil hook-wire
8
localization
8
lung nodules
8
vats resection
8
group relative
8
lung hemorrhage
8
group
6

Similar Publications

The widespread adoption of high-resolution computed tomography (CT) screening has led to increased detection of small pulmonary nodules, necessitating accurate localization techniques for surgical resection. This review examines the evolution, efficacy, and safety of various localization methods for small pulmonary nodules. Studies focusing on localization techniques for pulmonary nodules ≤30 mm in diameter were included, with emphasis on technical success rates and complication profiles.

View Article and Find Full Text PDF

A comparative study of 4-hook anchor device with methylene blue for preoperative pulmonary nodule localization.

Quant Imaging Med Surg

January 2025

Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Background: Accurate localization of small pulmonary nodules (SPNs) during video-assisted thoracoscopic surgery (VATS) is challenging due to the small size and deep location. Both the 4-hook wire technique and methylene blue are significant methods for preoperative localization of SPNs. This study aimed to compare the safety of both methods by monitoring and recording any surgery-related complications.

View Article and Find Full Text PDF

Background: Computed tomography (CT)-guided hook-wire localization is currently the most commonly used technique for preoperative localization of pulmonary nodules in clinical practice. With the increasing incidence of multiple primary lung cancers and the increasing occurrence of second primary lung cancers or local recurrences after lung cancer surgery, some patients need to undergo an ipsilateral or contralateral second pulmonary resection. In order to reduce the surgical difficulty of the second operation and accurately guide the surgical resection, preoperative localization of some nodules is necessary.

View Article and Find Full Text PDF

Comparison of different localization needles and postures in localization of pulmonary nodules.

J Cardiothorac Surg

December 2024

Department of Thoracic Surgery, The First Hospital of China Medical University, No. 155, Nanjing North Street, Shenyang, 110002, Liaoning, P.R. China.

Background: With advancements in imaging testing and surgical procedures, an increasing number of nodules with smaller diameters and deeper locations have been deemed suitable for surgical intervention. The preoperative localization of these nodules has become essential. In this retrospective single-center study, we aimed to compare the effectiveness and patient comfort associated with the use of a four-hook needle versus a hook-wire needle for preoperative localization.

View Article and Find Full Text PDF

Background And Objective: The early detection and early treatment of high-risk pulmonary nodules directly affect the long-term survival rate of patients. However, conventional nodule localization methods, such as hook-wire, technetium-99m, and methylene blue are associated with issues such as a high-frequency of complications, low patient tolerance, serious side effects, and inability to identify pigmented lungs. For patients who require segmentectomy, there is often a lack of effective path planning, resulting in insufficient resection margins or excessive loss of lung function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!