Meniscal tears are among the most common injuries in the knee, and partial as well as total meniscectomy has been advocated as the treatment for meniscal injury. Over the years, the role of the meniscus as a shock absorber, load transmitter, and secondary anterior stabilizer, along with its proprioceptive and lubrication role, has been well established, and meniscal repair is recommended, especially in younger individuals. Factors such as tear location, pattern, chronicity, size, and extent; repair technique; and patient age and habits can influence meniscal repair, and to enhance meniscal healing, a variety of augmentation techniques have been introduced. These include needling, trephination, synovial abrasion, and the use of adjuvants such as platelet-rich plasma, platelet clots, fibrin clots, bone marrow clots, and stem cells. A second-generation platelet derivative called "platelet-rich fibrin" (PRF) has predictable platelet, growth factor, and cell mediator concentrations without using any anticoagulants. We describe a reproducible and simple way to harvest PRF and create and use a PRF clot, along with detailed instructions on how to integrate the clot with a meniscal repair arthroscopically.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9519935PMC
http://dx.doi.org/10.1016/j.eats.2022.05.001DOI Listing

Publication Analysis

Top Keywords

meniscal repair
16
meniscal
6
repair
5
arthroscopic meniscal
4
repair second-generation
4
second-generation platelet-rich
4
platelet-rich fibrin
4
fibrin clot
4
clot augmentation
4
augmentation meniscal
4

Similar Publications

Background: To present rates of reporting bias in systematic reviews and meta-analyses investigating meniscal root repair.

Methods: In this systematic review, PubMed, Scopus and Web of Science databases were queried for studies that investigated meniscal root tears treated with root repair. Included studies were systematic reviews and/or meta-analyses published in peer-reviewed journals in the English language with available full-texts.

View Article and Find Full Text PDF

This Technical Note describes a surgical approach that combines circumferential fiber augmentation with transtibial pullout repair for the treatment of medial meniscal posterior root tears. To address the challenge of meniscal extrusion and subsequent joint space narrowing that predisposes to osteoarthritis, this technique uses an artificial ligament to add circumferential collagen fiber reinforcement to improve meniscal extrusion. This integrated approach is designed to address the limitations of conventional tibial pullout repairs by potentially providing better results in preventing meniscal extrusion.

View Article and Find Full Text PDF

Inside-out repair of meniscal tears is the gold standard surgical approach; however, its use is limited by the need for a posterior incision and neurovascular risk. In this Technical Report, we present details of the all-inside arthroscopic tie-grip approach for repairing a radial tear of the midbody of the lateral meniscus using an all-inside device (TRUESPAN) and a slotted cannula. In contrast to the inside-out approach, this technique helps reduce surgical invasiveness and provides stable fixation as the vertical mattress sutures bundle the circumferential fibers and act as rip stops for the horizontal sutures.

View Article and Find Full Text PDF

Dynamic biomechanical effects of medial meniscus tears on the knee joint: a finite element analysis.

J Orthop Surg Res

January 2025

Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.

Background: Meniscus tears can change the biomechanical environment of the knee joint and might accelerate the development of osteoarthritis. The aim of this study was to investigate the dynamic biomechanical effects of different medial meniscus tear positions and tear gaps on the knee during walking.

Methods: Seven finite element models of the knee joint were constructed, including the intact medial meniscus (IMM), radial stable tears in the anterior, middle, and posterior one-third regions of the medial meniscus (RSTA, RSTM, RSTP), and the corresponding unstable tears (RUTA, RUTM, RUTP).

View Article and Find Full Text PDF

Background: A growing body of evidence surrounds secondary meniscal and cartilage pathology after delay to anterior cruciate ligament (ACL) reconstruction (ACLR). Many of these studies focus on or include an adult population.

Purpose: To elucidate the prevalence of secondary meniscal and chondral pathology with delay to ACLR in the adolescent population as well as examine the influence of sex, skeletal maturity, and trends over the years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!