This study investigated the odor emission rate from different areas of a municipal solid waste landfill. The surface odor emission rate (SOER) of eight odorous compound groups were determined by flux chamber method. The SOER of working face, seams of daily cover, membrane surface of daily cover, seams of temporary cover, membrane surface of temporary cover, seams of intermediate cover, membrane surface of intermediate cover were 138.34, 49.83, 13.56, 90.35, 14.48, 4.05, and 8.14 μg/(m·s), respectively. Therefore, odor emission hotspots were at seams of daily and temporary cover areas. Converting the odor emissions at emission hotspots to the entire membrane cover surface, the average SOER of working face, daily cover area, temporary cover area and intermediate cover area were 138.34, 17.95, 22.43, and 6.24 μg/(m·s), respectively. Combined with the size of each landfill area, the total odor emissions of the four above areas of a landfill zone were 830, 108, 1346, and 5175 mg/s, respectively, suggesting the necessity to control the odor emission of membrane cover stages especially for large-scale landfills. In terms of odor components, alcohols (38.7 %), sulfur compounds (22.9 %) and aldehydes (15.7 %) were major odorous groups.