Background: Transcatheter repair of sinus venosus atrial septal defect (SVASD) has become an alternative option to surgical repair. There are potential significant complications related to stent stability in the superior vena cava (SVC) and potential migration of the stent that need to be addressed. Therefore, the technique is still evolving.

Objectives: To report results of a new modification "the suture technique" that improves safety profile of positioning and securing a covered stent in the SVC.

Methods: This is a descriptive, single center, retrospective review of patients who underwent SVASD closure using the suture technique at our institution between 02/2020 and 08/2022.

Results: Fourteen patients underwent transcatheter repair of SVASD using the suture technique. All procedures were successful. The suture technique allowed precise stent placement in all patients without any migration or complication. Six patients required additional stent placement at the level of the SVC. One patient had an additional covered stent placed to eliminate a tiny residual shunt. Two patients had negligible residual shunts at the time of the procedure. At follow-up, all patients clinically improved and had significant reduction in right heart size on echocardiography and/or magnetic resonance imaging. No arrhythmia was reported in any patient. None required re-intervention after a mean follow-up of 16.5 ± SD 10.5 months.

Conclusions: The suture technique appears to be safe modification. Although our study involves small sample size with no comparative group, we believe our technique offers greater control over stent positioning, reducing the risk of stent embolization and residual shunting in transcatheter closure of SVASD.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.30415DOI Listing

Publication Analysis

Top Keywords

suture technique
16
transcatheter closure
8
sinus venosus
8
venosus atrial
8
atrial septal
8
septal defect
8
transcatheter repair
8
stent
8
covered stent
8
patients underwent
8

Similar Publications

Introduction: Veno-Arterial Extracorporeal Membrane Oxygenation (VA-ECMO) has emerged as a crucial component of critical care medicine, mainly as a lifesaving intervention for patients experiencing refractory cardiac arrest and respiratory failure.

Background: In the past, VA-ECMO decannulation was surgical and often associated with a high rate of periprocedural complications, such as surgical site infection, bleeding, and patient mobilization costs. To reduce the rate of these adverse events, many percutaneous techniques utilizing suture-mediated closing devices have been adopted.

View Article and Find Full Text PDF

Suture material in pancreticojejunal anastomosis: a systematic review.

ANZ J Surg

January 2025

General Surgical Department, Liverpool Hospital, Corner of Elizabeth and Goulburn Street, Liverpool, New South Wales, 2170, Australia.

Background: Post-operative pancreatic fistula is a common and morbid complication of pancreaticojejunal anastomosis. While gastrointestinal anastomosis is typically performed using absorbable sutures, this issue has prompted experimentation with non-absorbable sutures. This study aims to assess the available literature to provide recommendations on suture choice in this anastomosis.

View Article and Find Full Text PDF

Background: Interest in biological augmentation for improving bone-tendon interface (BTI) healing after arthroscopic rotator cuff repair (ARCR) is growing. Dermal fibroblasts, known for collagen synthesis similar to tenocytes, have shown effectiveness in BTI healing in chronic rotator cuff tear (RCT) models in rabbits. However, no human clinical trials have been conducted.

View Article and Find Full Text PDF

Objective: Laparoscopic nephron sparing surgery (NSS) can be performed by mainly 2 methods, offclamp or on-clamp. Continuous bleeding during the off-clamp method may impair the clear visualization of the border between the tumor and parenchyma, even though it is done safely in experienced hands. Therefore, some surgical modifications may be needed during mass excision and renorraphy.

View Article and Find Full Text PDF

Revision quadriceps tendon repair: A case series and technique guide to a novel repair.

Trauma Case Rep

February 2025

Department of Orthopaedic Surgery and Sports Medicine, University at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Buffalo, NY 14203, United States of America.

Introduction: Revision quadriceps tendon repair is a challenging problem. In this four-case series, novel quadriceps tendon revision resulted in improved range of motion and durable repair for patients with recurrent rupture.

Methods: Our technique includes a combination of a running locked #5 FiberWire or 2 mm SutureTape suture placed through parallel medial, lateral, and central drill holes in the patella with running Krackow-type quadriceps tendon repair medially and laterally resulting in four strands, delivering the vastus medialis and medial quadriceps tendon to an anatomic repair at the superior pole of the patella, with 2 sutures passed centrally and 1 each passed medially and laterally and then tied.

View Article and Find Full Text PDF