Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ∼2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm and 2 × 40 μm geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper-where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0091348DOI Listing

Publication Analysis

Top Keywords

x-ray source
8
source
6
diffraction enhanced
4
enhanced imaging
4
imaging utilizing
4
utilizing laser
4
laser produced
4
produced x-ray
4
source image
4
image formation
4

Similar Publications

Nanoparticles-Based Optical Chemosensors for Lead Acetate Sensing in Water: ZnO, ZnCeO, and ZnNdO.

J Fluoresc

January 2025

Materials Science Lab (1), Physics Department, Faculty of Science, Cairo University, Giza, Egypt.

This study reports the synthesis, characterization, and optical properties of ZnO, ZnCeO, and ZnNdO nanoparticles and their interactions with lead acetate solutions. X-ray diffraction (XRD) confirmed that the nanoparticles were synthesized in a single-phase hexagonal structure, with crystallite sizes of 12.48 nm, 50.

View Article and Find Full Text PDF

Study Design: A cross-sectional analysis of 10,000 cervical spine X-rays.

Objective: This study investigates the variations in C6S and C7S across demographic factors (gender, age, cervical curvature, symptoms) and explores their correlation. Additionally, machine learning models are applied to improve the accuracy of C7S prediction.

View Article and Find Full Text PDF

Methane (CH), which is the main component of natural gas, is an abundant and widely available carbon resource. However, CH has a low energy density of only 36 kJ L under ambient conditions, which is significantly lower than that of gasoline (. 34 MJ L).

View Article and Find Full Text PDF

Echoes and Shadows: Predicting Hepatorenal Syndrome Outcomes with Lung Ultrasound and X-rays.

Indian J Crit Care Med

November 2024

Department of Anaesthesia, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, Maharashtra, India.

Kothekar AT, Shah KB. Echoes and Shadows: Predicting Hepatorenal Syndrome Outcomes with Lung Ultrasound and X-rays. Indian J Crit Care Med 2024;28(11):993-994.

View Article and Find Full Text PDF

Aim And Background: A combination of terlipressin and albumin is the standard of care for patients with hepatorenal syndrome-acute kidney injury (HRS-AKI). The study aimed to compare the venous congestion using lung ultrasound score (LUS) and radiographic assessment of lung edema (RALE) scores among terlipressin responders and nonresponders and survivors and non-survivors.

Materials And Methods: In this single-center, prospective, observational study, we included adult patients with HRS-AKI who had received terlipressin and albumin from 28th April 2022 to 16th October 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!