Scanning laser ophthalmoscopy retroillumination: applications and illusions.

Int J Retina Vitreous

Retina Department, Institute of Ophthalmology, Fundacion Conde de Valenciana, Chimalpopoca 14, Colonia Obrera, Cuauhtemoc, 06800, Mexico City, Mexico.

Published: September 2022

Scanning laser ophthalmoscopes (SLOs) are used widely for reflectance, fluorescence or autofluorescence photography and less commonly for retroillumination imaging. SLOs scan a visible light or near-infrared radiation laser beam across the retina, collecting light from each retinal spot as it's illuminated. An SLO's clinical applications, image contrast and axial resolution are largely determined by an aperture overlying its photodetector. High contrast, reflectance images are produced using small diameter, centered apertures (confocal apertures) that collect retroreflections and reject side-scattered veiling light returned from the fundus. Retroillumination images are acquired with annular on-axis or laterally-displaced off-axis apertures that capture scattered light and reject the retroreflected light used for reflectance imaging. SLO axial resolution is roughly 300 μm, comparable to macular thickness, so SLOs cannot provide the depth-resolved chorioretinal information obtainable with optical coherence tomography's (OCT's) 3 μm axial resolution. Retroillumination highlights and shades the boundaries of chorioretinal tissues and abnormalities, facilitating detection of small drusen, subretinal drusenoid deposits and subthreshold laser lesions. It also facilitates screening for large-area chorioretinal irregularities not readily identified with other en face retinal imaging modalities. Shaded boundaries create the perception of lesion elevation or depression, a characteristic of retroillumination but not reflectance SLO images. These illusions are not reliable representations of three-dimensional chorioretinal anatomy and they differ from objective OCT en face topography. SLO retroillumination has been a useful but not indispensable retinal imaging modality for over 30 years. Continuing investigation is needed to determine its most appropriate clinical roles in multimodal retinal imaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9524008PMC
http://dx.doi.org/10.1186/s40942-022-00421-0DOI Listing

Publication Analysis

Top Keywords

axial resolution
12
retinal imaging
12
scanning laser
8
retroillumination
6
imaging
5
light
5
laser ophthalmoscopy
4
ophthalmoscopy retroillumination
4
retroillumination applications
4
applications illusions
4

Similar Publications

Coherent lensless imaging usually suffers from coherent noise and twin-image artifacts. In the terahertz (THz) range, where wavelengths are 2 to 4 orders of magnitude longer than those in the visible spectrum, the coherent noise manifests primarily as parasitic interference fringes and edge diffraction, rather than speckle noise. In this work, to suppress the Fabry-Pérot (F-P) interference fringes, we propose a novel method, which involves the averaging over multiple diffraction patterns that are acquired at equal intervals within a sample's half-wavelength axial shift.

View Article and Find Full Text PDF

Background: Computed tomography (CT) is the gold standard imaging modality for the assessment of 3D bony morphology but incurs the cost of ionizing radiation exposure. High-resolution 3D magnetic resonance imaging (MRI) with CT-like bone contrast (CLBC) may provide an alternative to CT in allowing complete evaluation of both bony and soft tissue structures with a single MRI examination.

Purpose: To review the technical aspects of an optimized stack-of-stars 3D gradient recalled echo pulse sequence method (3D-Bone) in generating 3D MR images with CLBC, and to present a pictorial review of the utility of 3D-Bone in the clinical assessment of common musculoskeletal conditions.

View Article and Find Full Text PDF

Wearable optical coherence tomography angiography probe with extended depth of field.

J Biomed Opt

January 2025

Tsinghua University, State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing, China.

Significance: Optical coherence tomography (OCT) is widely utilized to investigate brain activities and disorders in anesthetized or restrained rodents. However, anesthesia can alter several physiological parameters, leading to findings that might not fully represent the true physiological state. To advance the understanding of brain function in awake and freely moving animals, the development of wearable OCT probes is crucial.

View Article and Find Full Text PDF

Background: With increasing evidence supporting three-dimensional (3D) automated breast (AB) ultrasound (US) for supplemental screening of breast cancer in increased-risk populations, including those with dense breasts and in limited-resource settings, there is an interest in developing more robust, cost-effective, and high-resolution 3DUS imaging techniques. Compared with specialized ABUS systems, our previously developed point-of-care 3D ABUS system addresses these needs and is compatible with any conventional US transducer, which offers a cost-effective solution and improved availability in clinical practice. While conventional US transducers have high in-plane resolution (axial and lateral), their out-of-plane resolution is constrained by the poor intrinsic elevational US resolution.

View Article and Find Full Text PDF

Anatomical configuration of the MB2 canal using high-resolution CBCT.

J Endod

January 2025

Faculdade São Leopoldo Mandic, Instituto de pesquisas São Leopoldo Mandic, Departamento de Endodontia, Campinas, São Paulo, Brasil.

Objective: This study aims to evaluate the anatomical configuration of the mesiobuccal root of the maxillary first molar and assess the prevalence of the mesiobuccal canal (MB2).

Materials And Methods: A total of 307 high-resolution cone-beam computed tomography (CBCT) images of maxillary molars were analyzed. These images were classified based on the anatomical configuration and prevalence of the MB2 canal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!