Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The Q suture has been reported to be an effective alternative to conventional peripheral sutures in tendon repair. Whether the Q method can be used as a core suture rather than a peripheral suture by adjusting the purchase length is unknown. We tested a double Q suture technique with variable purchase length and studied its effects on gap formation and tensile strength using an ex vivo model.
Methods: Forty pig flexor tendons were repaired using the double Q sutures with purchase lengths of 2, 4, 6, and 8 mm. Twenty tendons repaired using the double Tsuge and double Kessler sutures with an 8-mm purchase length were used as controls. The tendons were subjected to cyclic loading and load-to-failure. The number of tendons that formed an initial or 2-mm gap between the tendon ends, gap distance at the repair site, stiffness, and ultimate strength were recorded.
Results: During cyclic loading, the double Q suture with a 4-8-mm purchase had fewer tendons form an initial or 2-mm gap and a smaller gap size at the repair site than the Tsuge and Kessler sutures. The stiffness of the double Q suture with a 6-8-mm purchase length and Tsuge suture was greater than those of the double Kessler suture. The double Q suture with a 2-mm purchase length had smaller ultimate strength than the other sutures.
Conclusions: The Q suture may be an effective tendon repair method whose role can be converted between peripheral and core sutures via adjusting the suture purchase length. With an optimal suture length of 4-6 mm, the double Q method had tensile resistance superior to 4-strand core sutures.
Clinical Relevance: The double Q suture may be a viable option as a core suture in flexor tendon repair when the purchase length is appropriately adjusted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhsa.2022.08.002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!