A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and application of a membrane assisted solvent extraction-molecularly imprinted polymer based passive sampler for monitoring of selected pharmaceuticals in surface water. | LitMetric

In this work, we demonstrate the development, evaluation and pre-liminary application of a novel passive sampler for monitoring of selected pharmaceuticals in environmental waters. The samplers were calibrated in laboratory-based experiments to obtain sampling rates (Rs) for carbamazepine, methocarbamol, etilefrine, venlafaxine and nevirapine. Passive sampling was based on the diffusion of the target pharmaceuticals from surface water through a membrane bag which housed an ionic liquid as a green receiving solvent and a molecularly imprinted polymer. Effects of biofouling, deployment time and solvent type for the receiver phase were optimized for selective uptake of analytes in surface water. Notably, there was a decrease in the uptake of selected pharmaceuticals and consequently a decrease in their sampling rates in the presence of biofouling. The optimum matrix-matched sampling rates ranged from 0.0007 - 0.0018 L d whilst the method detection and quantification limits ranged from 2.45 - 3.26 ng L and 8.06 - 10.81 ng L, respectively. The optimized passive sampler was deployed in a dam situated in the heart of a typical highly populated township in the Gauteng Province of South Africa. Only etilefrine and methocarbamol were detected and quantified at maximum time weighted average concentrations of 12.88 and 72.29 ng L, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2022.119145DOI Listing

Publication Analysis

Top Keywords

passive sampler
12
selected pharmaceuticals
12
surface water
12
sampling rates
12
imprinted polymer
8
sampler monitoring
8
monitoring selected
8
pharmaceuticals surface
8
development application
4
application membrane
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!