A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparing the Usability of Alternative EEG Devices to Traditional Electrode Caps for SSVEP-BCI Controlled Assistive Robots. | LitMetric

Despite having the potential to improve the lives of severely paralyzed users, non-invasive Brain Computer Interfaces (BCI) have yet to be integrated into their daily lives. The widespread adoption of BCI-driven assistive technology is hindered by its lacking usability, as both end-users and researchers alike find fault with traditional EEG caps. In this paper, we compare the usability of four EEG recording devices for Steady-State Visually Evoked Potentials (SSVEP)-BCI applications: an EEG cap (active gel electrodes), two headbands (passive gel or active dry electrodes), and two adhesive electrodes placed on each mastoid. Ten able-bodied participants tested each device by completing an 8-target SSVEP paradigm. Setup times were recorded, and participants rated their satisfaction with each device. The EEG cap obtained the best classification accuracies (Median = 98.96%), followed by the gel electrode headband (Median = 93.75%), and the dry electrode headband (Median = 91.14%). The mastoid electrodes obtained classification accuracies close to chance level (Med = 29.69%). Unknowing of the classification accuracy, participants found the mastoid electrodes to be the most comfortable and discrete. The dry electrode headband obtained the lowest user satisfaction score and was criticized for being too uncomfortable. Participants also noted that the EEG cap was too conspicuous. The gel-based headband provided a good trade-off between BCI performance and user satisfaction.

Download full-text PDF

Source
http://dx.doi.org/10.1109/ICORR55369.2022.9896588DOI Listing

Publication Analysis

Top Keywords

eeg cap
12
electrode headband
12
classification accuracies
8
headband median
8
dry electrode
8
mastoid electrodes
8
user satisfaction
8
eeg
6
electrodes
5
comparing usability
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!