Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Dental health care personnel (DHCP) may be at increased risk of exposure to severe acute respiratory syndrome coronavirus 2, the virus that causes COVID-19, as well as other clinically important pathogens. Proper use of personal protective equipment (PPE) reduces occupational exposure to pathogens. The authors performed an assessment of PPE donning and doffing practices among DHCP, using a fluorescent marker as a surrogate for pathogen transmission.
Methods: Participants donned PPE (that is, disposable gown, gloves, face mask, and eye protection) and the fluorescent marker was applied to their palms and abdomen. DHCP then doffed PPE according to their usual practices. The donning and doffing processes were video recorded, areas of fluorescence were noted, and protocol deviations were assessed. Statistical analyses included frequency, type, and descriptions of protocol deviations and factors associated with fluorescence.
Results: Seventy DHCP were enrolled. The donning and doffing steps with the highest frequency of protocol deviations were hand hygiene (66% of donning and 78% of doffing observations involved a deviation) and disposable gown use (63% of donning and 60% of doffing observations involved a deviation). Fluorescence was detected on 69% of DHCP after doffing, most frequently on hands. An increasing number of protocol deviations was significantly associated with increased risk of fluorescence. DHCP with a gown doffing deviation, excluding doffing out of order, were more likely to have fluorescence detected.
Conclusions: DHCP self-contamination was common with both donning and doffing PPE.
Practical Implications: Proper use of PPE is an important component of occupational health.