Background: A method using in vivo Cine IVUS and VH-IVUS data has been proposed to quantify material properties of coronary plaques. However, correlations between plaque morphological characteristics and mechanical properties have not been studied in vivo.
Method: In vivo Cine IVUS and VH-IVUS data were acquired at 32 plaque cross-sections from 19 patients. Six morphological factors were extracted for each plaque. These samples were categorized into healthy vessel, fibrous plaque, lipid-rich plaque and calcified plaque for comparisons. Three-dimensional thin-slice models were constructed using VH-IVUS data to quantify in vivo plaque material properties following a finite element updating approach by matching Cine IVUS data. Effective Young's moduli were calculated to represent plaque stiffness for easy comparison. Spearman's rank correlation analysis was performed to identify correlations between plaque stiffness and morphological factor. Kruskal-Wallis test with Bonferroni correction was used to determine whether significant differences in plaque stiffness exist among four plaque groups.
Result: Our results show that lumen circumference change has a significantly negative correlation with plaque stiffness (r = -0.7807, p = 0.0001). Plaque burden and calcification percent also had significant positive correlations with plaque stiffness (r = 0.5105, p < 0.0272 and r = 0.5312, p < 0.0193) respectively. Among the four categorized groups, calcified plaques had highest stiffness while healthy segments had the lowest.
Conclusion: There is a close link between plaque morphological characteristics and mechanical properties in vivo. Plaque stiffness tends to be higher as coronary atherosclerosis advances, indicating the potential to assess plaque mechanical properties in vivo based on plaque compositions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2022.09.051 | DOI Listing |
Eur Heart J Case Rep
January 2025
Cardiovascular and Thoracic Division, Cardiology Department, University Hospital Southampton, Tremona Road, Southampton SO16 6YD, UK.
Background: Takotsubo cardiomyopathy usually presents with acute reversible left ventricular apical hypokinesia and apical ballooning with basal hyperdynamic function. We describe an underreported case of Takotsubo cardiomyopathy (TCM), misinterpreted as apical hypertrophic cardiomyopathy (HCM) due to transient apical oedema in the recovery phase of the condition.
Case Summary: A 74-year-old Caucasian woman, presented to the emergency department complaining of retrosternal chest pain following, emotional stress.
Biomech Model Mechanobiol
January 2025
Cardiac Surgery Division, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, USA.
Percutaneous coronary interventions in highly calcified atherosclerotic lesions are challenging due to the high mechanical stiffness that significantly restricts stent expansion. Intravascular lithotripsy (IVL) is a novel vessel preparation technique with the potential to improve interventional outcomes by inducing microscopic and macroscopic cracks to enhance stent expansion. However, the exact mechanism of action for IVL is poorly understood, and it remains unclear whether the improvement in-stent expansion is caused by either the macro-cracks allowing the vessel to open or the micro-cracks altering the bulk material properties.
View Article and Find Full Text PDFMatrix Biol
January 2025
Department of Surgery, Emory University, Atlanta, GA, USA; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA; Research Services, Atlanta VA Medical Center, Decatur, GA, USA. Electronic address:
Arterial endothelial cells (ECs) reside in a complex biomechanical environment. ECs sense and respond to wall shear stress. Low and oscillatory wall shear stress is characteristic of disturbed flow and commonly found at arterial bifurcations and around atherosclerotic plaques.
View Article and Find Full Text PDFCureus
December 2024
Medical Affairs, Dr. Reddy's Laboratories Ltd., Hyderabad, IND.
Background Toothbrush manufacturers commonly use bristle materials such as nylon, polybutylene terephthalate, polypropylene, polyethylene terephthalate, boar hair, bamboo, carbon fiber, silicone, polylactic acid, or their modifications such as Curen. Nylon filaments have long been demonstrated to be durable and are widely used, but not much is known regarding the performance of Curen filaments compared to nylon filaments. This in vitro study compared the stiffness, abrasion potential, abrasion resistance, and bristle surface changes of Curen and nylon filaments.
View Article and Find Full Text PDFJ Imaging Inform Med
January 2025
Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-Ro 43-Gil, Seoul, 05505, Republic of Korea.
Although the relationships between basic clinical parameters and white matter hyperintensity (WMH) have been studied, the associations between vascular factors and WMH volume in general populations remain unclear. We investigated the associations between clinical parameters including comprehensive vascular factors and WMH in two large general populations. This retrospective, cross-sectional study involved two populations: individuals who underwent general health examinations at the Asan Medical Center (AMC) and participants from a regional cohort, the Korean Genome and Epidemiology Study (KoGES).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!