A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modelling the impacts of operational conditions on the performance of a full-scale membrane aerated biofilm reactor. | LitMetric

Modelling the impacts of operational conditions on the performance of a full-scale membrane aerated biofilm reactor.

Sci Total Environ

PROSYS Research Center, Department of Chemical and Biochemical Engineering, Technical University of Denmark, Søltofts Plads 228A, Kgs. Lyngby 2800, Denmark. Electronic address:

Published: January 2023

Membrane Aerated Biofilm Reactors (MABR) are gaining more and more acceptance in the plethora of wastewater process intensification technologies. Mathematical modelling has contributed to show their feasibility in terms of reduced energy consumption and footprint. Nevertheless, most simulation studies published until now are still focused on analyzing MABR as single units and not fully integrated within the flow diagram of the water treatment plant (WWTP). In this paper, the prediction capabilities of an integrated modelling approach is tested using full-scale data from Ejby Mølle WWTP+MABR site (Odense, Denmark). Mass balances, data reconciliation methods, process simulation and the different evaluation criteria were used to adjust influent, effluent and process indicators. Results show 10 % mismatch between flow, COD, N and P predictions and measurements in different plant locations. Using the adopted hydraulic retention time (HRT), nitrogen load (NL), membrane surface area (MA) and oxygen transfer rate (OTR), it was possible to predict nitrification rates (NR) within the interquartile range. This has been done under two different MABR operational conditions: with (#S2) and without (#S1) external aeration (EA) in the bulk liquid. The model provides additional process insights about biofilm structure, substrate gradients, weak acid base chemistry and precipitation potential. More specifically, simulations suggest the potential undesirable effects of sulfate (SRB) and iron reducing bacteria (IRB) on both microbial activity and composition of the biofilm. The latter may have a strong impact on ammonium (NH), sulfate (SO) and ferrous ion (Fe) conversion processes. The change of operational strategy in the scenario analysis highlights that the denitrifying activity of phosphorus accumulating organisms (PAOs) can enhance nutrient removal in MABR tanks. In addition, it was possible to assess the chance of success (in terms of energetic cost of nitrogen removal) of adding several MABR units in one tank of the WWTP under study before full-scale implementation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2022.158980DOI Listing

Publication Analysis

Top Keywords

operational conditions
8
membrane aerated
8
aerated biofilm
8
mabr
5
modelling impacts
4
impacts operational
4
conditions performance
4
performance full-scale
4
full-scale membrane
4
biofilm
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!