Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The COVID-19 pandemic created the need for large-scale testing of populations. However, most laboratories do not have sufficient testing capacity for mass screening. We evaluated pooled testing of samples, as a strategy to increase testing capacity in Lao PDR. Samples of consecutive patients were tested in pools of four using the Xpert Xpress SARS CoV-2 assay. Positive pools were confirmed by individual testing, and we describe the performance of the test and savings achieved. We also diluted selected positive samples to describe its effect on the assays CT values. 1,568 patients were tested in 392 pools of four. 361 (92.1%) pools were negative and 31 (7.9%) positive. 29/31 (93.5% (95%CI 77-99%) positive pools were confirmed by individual testing of the samples but, in 2/31 (6.5%) the four individual samples were negative, suggesting contamination. Pools with only one positive sample had higher CT values (lower RNA concentrations) than the respective individual samples, indicating a dilution effect, which suggested an increased risk of false negative results with dilutions >1:10. However, this risk may be low if the prevalence of infection is high, when pools are more likely to contain more than one positive sample. Pooling saved 67% of cartridges and substantially increased testing capacity. Pooling samples increased SARS-CoV-2 testing capacity and resulted in considerable cartridge savings. Given the need for high-volume testing, countries may consider implementation of pooling for SARS-CoV-2 screening.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9522287 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0275294 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!