A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

3D-Printed Radiopaque Bioresorbable Stents to Improve Device Visualization. | LitMetric

3D-Printed Radiopaque Bioresorbable Stents to Improve Device Visualization.

Adv Healthc Mater

Center for Advanced Regenerative Engineering (CARE), Northwestern University, Evanston, IL, 60208, USA.

Published: December 2022

Bioresorbable stents (BRS) hold great promise for the treatment of many life-threatening luminal diseases. Tracking and monitoring of stents in vivo is critical for avoiding their malposition and inadequate expansion, which often leads to complications and stent failure. However, obtaining high X-ray visibility of polymeric BRS has been challenging because of their intrinsic radiolucency. This study demonstrates the use of photopolymerization-based 3D printing technique to fabricate radiopaque BRS by incorporating iodixanol, a clinical contrast agent, into a bioresorbable citrate-based polymer ink. The successful volumetric dispersion of the iodixanol through the 3D-printing process confers strong X-ray visibility of the produced BRS. Following in vitro degradation, the 3D-printed BRS embedded in chicken muscle maintains high X-ray visibility for at least 4 weeks. Importantly, the 3D-printed radiopaque BRS demonstrates good cytocompatibility and strong mechanical competence in crimping and expansion, which is essential for minimally invasive stent deployment. In addition, it is found that higher loading concentrations of iodixanol, e.g. 10 wt.%, results in more strut fractures in stent crimping and expansion. To conclude, this study introduces a facile strategy to fabricate radiopaque BRS through the incorporation of iodixanol in the 3D printing process, which could potentially increase the clinical success of BRS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9742307PMC
http://dx.doi.org/10.1002/adhm.202201955DOI Listing

Publication Analysis

Top Keywords

x-ray visibility
12
radiopaque brs
12
3d-printed radiopaque
8
bioresorbable stents
8
brs
8
high x-ray
8
fabricate radiopaque
8
crimping expansion
8
radiopaque bioresorbable
4
stents improve
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!