Objectives: Gantry-free cone-beam CT (CBCT) allows for comfortable patient positioning due to an open scanner architecture. Since CBCT without gantry is not yet established for clinical wrist trauma imaging, this study's aim was to investigate its diagnostic value in the preoperative workup of patients with distal radius and scaphoid fractures.
Methods: Within a 12-month period, 113 patients with severe wrist trauma underwent both radiography and CBCT with the same gantry-free multi-use scanner before surgery. Two radiologists retrospectively analyzed all datasets for the morphology of distal radius (n = 95) and scaphoid fractures (n = 20). In all 115 wrists (two bilateral injuries), surgical reports served as the standard of reference.
Results: While accuracy for distal radius fractures was comparable among CBCT and radiographs, the former was superior with regard to scaphoid fractures (Reader 1: 100.0% vs. 75.0%; Reader 2: 100.0% vs. 65.0%). Accuracy for multi-fragmentary radius injuries (100.0% vs. 90.5%; 100.0% vs. 93.7%), and articular affliction (99.0% vs. 84.2%; 100.0% vs. 83.2%) was also higher in CBCT. Regarding scaphoid fractures, CBCT proved superior for diagnosis of proximal pole or waist involvement (100.0% vs. 70.0%; 100.0% vs. 65.0%) and comminuted patterns (100.0% vs. 70.0%; 100.0% vs. 75.0%). Median effective dose of CBCT was as low as 3.65 µSv compared with 0.16 µSv for standard radiography.
Conclusion: Gantry-free CBCT allows for excellent diagnostic accuracy in the assessment of distal radius and scaphoid fracture morphology. Even in patients with limited mobility, very low radiation dose is sufficient to maintain high image quality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.acra.2022.08.030 | DOI Listing |
Osteoporos Int
January 2025
Department of Orthopaedic Surgery, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-8510, Japan.
Unlabelled: Metaphyseal comminution in distal radius fracture (DRF) cases might indicate severe osteoporosis. The patients with DRFs and metaphyseal comminution showed 5.2-fold increased secondary fractures compared with those receiving combination osteoporosis therapy.
View Article and Find Full Text PDFTrauma Case Rep
February 2025
Department of Orthopaedics and Spine Surgery, Ganga Medical Centre & Hospitals Pvt Ltd, Coimbatore, Tamil Nadu, India.
Case: A 52-year-old male fell from his bike and sustained fractures of the right proximal humerus and the left distal radius, both of which were fixed in a single sitting a day after the injury. On postoperative day four, the patient developed features suggestive of acute pulmonary embolism.
Conclusion: Reports of acute pulmonary embolism developing after surgical fixation of bilateral upper extremity fractures are rare.
Shoulder Elbow
January 2025
Department of Shoulder & Elbow, Orthopedic Institute, Sioux Falls, SD, USA.
Background: Distal biceps tendon rupture is an injury that causes a significant reduction in strength and endurance. Combined cortical button and interference screw fixation has been utilized via single-incision technique. There are limited data describing this technique utilizing a double-incision approach.
View Article and Find Full Text PDFBone Rep
March 2025
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, United States of America.
High resolution peripheral quantitative computed tomography (HRpQCT) offers detailed bone geometry and microarchitecture assessment, including cortical porosity, but assessing chronic kidney disease (CKD) bone images remains challenging. This proof-of-concept study merges deep learning and machine learning to 1) improve automatic segmentation, particularly in cases with severe cortical porosity and trabeculated endosteal surfaces, and 2) maximize image information using machine learning feature extraction to classify CKD-related skeletal abnormalities, surpassing conventional DXA and CT measures. We included 30 individuals (20 non-CKD, 10 stage 3 to 5D CKD) who underwent HRpQCT of the distal and diaphyseal radius and tibia and contributed data to develop and validate four different AI models for each anatomical site.
View Article and Find Full Text PDFAm J Case Rep
January 2025
Department of Orthopaedics, Juntendo University Faculty of Medicine, Tokyo, Japan.
BACKGROUND Extensor pollicis longus (EPL) tendon rupture is a potential complication following distal radius fracture, typically occurring several weeks after injury. Herein, we present a rare case of acute extensor pollicis longus tendon rupture associated with a distal radius fracture. CASE REPORT A 35-year-old woman visited our hospital with a distal radius fracture.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!