AI Article Synopsis

  • The guidelines from the European Association of Nuclear Medicine (EANM) focus on quality control (QC) for PET-CT and PET-MR systems, building on previous nuclear medicine standards while addressing the unique features of these multimodal scanners.
  • They provide a detailed overview of essential quality control procedures to keep PET systems functioning optimally in clinical settings, along with discussions on regulatory frameworks from the International Electrotechnical Commission (IEC) and European Commission (EC).
  • The recommendations include the rationale for various tests, their suggested frequency, specific tests for MR and CT integration, and a preventive approach to maintain acceptable performance levels in routine clinical use.

Article Abstract

We present guidelines by the European Association of Nuclear Medicine (EANM) for routine quality control (QC) of PET-CT and PET-MR systems. These guidelines are partially based on the current EANM guidelines for routine quality control of Nuclear Medicine instrumentation but focus more on the inherent multimodal aspect of the current, state-of-the-art PET-CT and PET-MR scanners. We briefly discuss the regulatory context put forward by the International Electrotechnical Commission (IEC) and European Commission (EC) and consider relevant guidelines and recommendations by other societies and professional organizations. As such, a comprehensive overview of recommended quality control procedures is provided to ensure the optimal operational status of a PET system, integrated with either a CT or MR system. In doing so, we also discuss the rationale of the different tests, advice on the frequency of each test and present the relevant MR and CT tests for an integrated system. In addition, we recommend a scheme of preventive actions to avoid QC tests from drifting out of the predefined range of acceptable performance values such that an optimal performance of the PET system is maintained for routine clinical use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10068535PMC
http://dx.doi.org/10.1016/j.zemedi.2022.08.003DOI Listing

Publication Analysis

Top Keywords

quality control
16
pet-ct pet-mr
12
routine quality
12
eanm guidelines
8
nuclear medicine
8
pet system
8
integrated system
8
guidelines pet-ct
4
routine
4
pet-mr routine
4

Similar Publications

Reconstruction of the anterior cruciate ligament (ACL) using hamstring autograft presents a greater risk of surgical site infection than other transplants (0.5% to 1.5%).

View Article and Find Full Text PDF

Introduction: Suffering from chronic pain (CP) and coping with parenthood can be challenging for parental mental health. Pain can hinder the ability to deal with demands related to parenthood, which can negatively affect their psychological well-being because of unmet caregiving expectations.

Methods: Considering the limited amount of research regarding the mental health of parents with CP, the study's main aim was to test a predictive model based on previous scientific literature, using structural equation analysis, in which parental competence and parental guilt partially mediate the relationship between parental stress and depression.

View Article and Find Full Text PDF

The popularity of roasted pork among Chinese consumers is largely attributed to its rich aroma profile. However, the suitability of different pork species for roasting remains uncertain. In this study, the effect of various pork species on the aroma profiles of roasted pork was systematically investigated using gas chromatography-olfactometry-mass spectrometry (GC-O-MS).

View Article and Find Full Text PDF

Background: Chronic illness research has many challenges making research recruitment difficult. Despite reports of facilitators and barriers to research recruitment challenges remain. The reporting of research strategies and their impact on recruitment and subsequent randomised control trials is not sufficient.

View Article and Find Full Text PDF

Background: Continuous glucose monitoring (CGM) improves glycemic control and quality of life. Data on glycemic indices and fear of hypoglycemia (FoH) in newly diagnosed T1DM patients are limited.

Aim: To assess the impact of initiating intermittently scanned CGM (isCGM) within 1-6 months of diagnosis on glycemic control and FoH in adults with T1DM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!