Purpose: The aim of this study was to evaluate strategies to reduce contrast media volumes for coronary computed tomography (CT) angiography on a clinical first-generation dual-source photon-counting detector (PCD)-CT system using a dynamic circulation phantom.
Materials And Methods: Coronary CT angiograph is an established method for the assessment of coronary artery disease that relies on the administration of iodinated contrast media. Reduction of contrast media volumes while maintaining diagnostic image quality is desirable. In this study, a dynamic phantom containing a 3-dimensional-printed model of the thoracic aorta and coronary arteries was evaluated using a clinical contrast injection protocol with stepwise reduced contrast agent concentrations (100%, 75%, 50%, 40%, 30%, and 20% contrast media content of the same 50 mL bolus, resulting in iodine delivery rates of 1.5, 1.1, 0.7, 0.6, 0.4 and 0.3 gl/s) on a first-generation, dual-source PCD-CT. Polychromatic images (T3D) and virtual monoenergetic images were reconstructed in the range of 40 to 70 keV in 5-keV steps. Attenuation and noise were measured in the coronary arteries and background material and the contrast-to-noise ratio (CNR) were calculated. Attenuation of 350 HU and a CNR of the reference protocol at 70 keV were regarded as sufficient for simulation of diagnostic purposes. Vessel sharpness and noise power spectra were analyzed for the aforementioned reconstructions.
Results: The standard clinical contrast protocol (bolus with 100% contrast) yielded diagnostic coronary artery attenuation for all tested reconstructions (>398 HU). A 50% reduction in contrast media concentration demonstrated sufficient attenuation of the coronary arteries at 40 to 55 keV (>366 HU). Virtual monoenergetic image reconstructions of 40 to 45 and 40 keV allowed satisfactory attenuation of the coronary arteries for contrast concentrations of 40% and 30% of the original protocol. A reduction of contrast agent concentration to 20% of the initial concentration provided insufficient attenuation in the target vessels for all reconstructions. The highest CNR was found for virtual monoenergetic reconstructions at 40 keV for all contrast media injection protocols, yielding a sufficient CNR at a 50% reduction of contrast agent concentration.
Conclusions: Using virtual monoenergetic image reconstructions at 40 keV on a dual-source PCD-CT system, contrast media concentration could be reduced by 50% to obtain diagnostic attenuation and objective image quality for coronary CT angiography in a dynamic vessel phantom. These initial feasibility study results have to be validated in clinical studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RLI.0000000000000911 | DOI Listing |
Sci Rep
January 2025
Department of Radiation Oncology, Henry Ford Hospital, Detroit, USA.
Best current practice in the analysis of dynamic contrast enhanced (DCE)-MRI is to employ a voxel-by-voxel model selection from a hierarchy of nested models. This nested model selection (NMS) assumes that the observed time-trace of contrast-agent (CA) concentration within a voxel, corresponds to a singular physiologically nested model. However, admixtures of different models may exist within a voxel's CA time-trace.
View Article and Find Full Text PDFBMJ Sex Reprod Health
January 2025
Obstetrics and Gynaecology, University of Edinburgh, Edinburgh, UK.
Background: Recent media attention has been given to an apparent shift away from hormonal methods of contraception. While an increase in fertility awareness-based or 'natural' family planning methods is reported in the grey literature, there are no robust data to determine any such trend in the UK.
Methods: We compared self-reported contraceptive use at conception among patients presenting for abortion at British Pregnancy Advisory Service from January to June 2018 (N=33 495) and January to June 2023 (N=55 055) using chi-square (χ) tests of association.
Insights Imaging
January 2025
Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1, Berlin, Germany.
Objectives: To survey physicians' views on the risks and benefits of computed tomography (CT) in the management of septic patients and indications for and contraindications to contrast media use in searching for septic foci.
Methods: A web-based questionnaire was administered to physicians at a large European university medical center in January 2022. A total of 371 questionnaires met the inclusion criteria and were analyzed with physicians' work experience, workplace, and medical specialty as independent variables.
Mikrochim Acta
January 2025
Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, 030024, China.
African swine fever (ASF) is an acute hemorrhagic disease in pigs caused by the African swine fever virus (ASFV), which has a high mortality rate and brought great damage to global pig farming industry. At present, there is no effective treatment or vaccine to combat ASFV infection, so early detection of ASFV has become particularly important. Therefore, the PDMS/chitosan/MPMs composite film was proposed to detect ASFV P72.
View Article and Find Full Text PDFCan Assoc Radiol J
January 2025
Department of Radiology, Dalhousie University, Halifax, NS, Canada.
Contrast media, including iodinated contrast media and gadolinium-based contrast agents, are commonly administered pharmaceuticals with excellent safety profiles. However, a minority of the population may experience a hypersensitivity reaction following intravenous administration. Hypersensitivity reactions can be immediate or delayed, and range from mild, such as urticaria, to severe, including anaphylaxis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!